Contact force-guided catheter ablation for the treatment of atrial fibrillation: a meta-analysis of randomized, controlled trials

التفاصيل البيبلوغرافية
العنوان: Contact force-guided catheter ablation for the treatment of atrial fibrillation: a meta-analysis of randomized, controlled trials
المؤلفون: Qi, Z., Luo, X., Wu, B., Shi, H., Jin, B., Wen, Z.
المصدر: Brazilian Journal of Medical and Biological Research. March 2016 49(3)
بيانات النشر: Associação Brasileira de Divulgação Científica, 2016.
سنة النشر: 2016
مصطلحات موضوعية: Atrial fibrillation, Contact force sensing, Meta-analysis, Randomized, controlled trials
الوصف: Contact force (CF) sensing technology allows real-time monitoring during catheter ablation for atrial fibrillation (AF). However, the effect of CF sensing technology on procedural parameters and clinical outcomes still needs clarification. Because of the inconsistent results thus far in this area, we performed a meta-analysis to determine whether CF sensing technology can improve procedural parameters and clinical outcomes for the treatment of AF. Studies examining the benefits of CF sensing technology were identified in English-language articles by searching the MEDLINE, Web of Science, and Cochrane Library databases (inception to May 2015). Ten randomized, controlled trials involving 1834 patients (1263 males, 571 females) were included in the meta-analysis (681 in the CF group, 1153 in the control group). Overall, the ablation time was significantly decreased by 7.34 min (95%CI=-12.21 to -2.46; P=0.003, Z test) in the CF group compared with the control group. CF sensing technology was associated with significantly improved freedom from AF after 12 months (OR=1.55, 95%CI=1.20 to 1.99; P=0.0007) and complications were significantly lower in the CF group than in the control group (OR=0.50, 95%CI=0.29 to 0.87; P=0.01). However, fluoroscopy time analysis showed no significantly decreased trend associated with CF-guided catheter ablation (weighted mean difference: -2.59; 95%CI=-9.06 to 3.88; P=0.43). The present meta-analysis shows improvement in ablation time and freedom from AF after 12 months in AF patients treated with CF-guided catheter ablation. However, CF-guided catheter ablation does not decrease fluoroscopy time.
نوع الوثيقة: article
وصف الملف: text/html
اللغة: English
تدمد: 0100-879X
DOI: 10.1590/1414-431X20155127
URL الوصول: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2016000300707
Rights: info:eu-repo/semantics/openAccess
رقم الانضمام: edssci.S0100.879X2016000300707
قاعدة البيانات: SciELO
الوصف
تدمد:0100879X
DOI:10.1590/1414-431X20155127