Academic Journal

Injecting hemostatic matrix in the path of biopsies: efficacy, potential complications, and the management of such complications

التفاصيل البيبلوغرافية
العنوان: Injecting hemostatic matrix in the path of biopsies: efficacy, potential complications, and the management of such complications
المؤلفون: Rahal Junior, Antonio, Falsarella, Priscila Mina, Ferreira, Vinicius Tadeu Rodrigues, Mariotti, Guilherme Cayres, Queiroz, Marcos Roberto Gomes de, Garcia, Rodrigo Gobbo
المصدر: Radiologia Brasileira. April 2018 51(2)
بيانات النشر: Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem, 2018.
سنة النشر: 2018
مصطلحات موضوعية: Hemostatic techniques, Hemostatics/administration & dosage, Biopsy, needle/methods, Hemorrhage/prevention & control
الوصف: Objective: To describe the technique of injecting hemostatic matrix, as well as the experience of our interventional radiology department in its application. Materials and Methods: We conducted a single-center study with retrospective analysis of the experience of our group in the use of hemostatic gelatin matrix in percutaneous biopsies. Results: In a total of 73 biopsies in different organs, such as the liver, kidney, and spleen, hemostatic gelatin matrix was introduced into the coaxial needle. The only complication observed was migration of the hemostatic matrix to the left kidney collecting system, and that was resolved with clinical treatment. There were no cases of bleeding after the injection of hemostatic matrix. Conclusion: The use of hemostatic matrices in the path of percutaneous biopsies is another tool available for consideration in minimally invasive procedures.
نوع الوثيقة: article
وصف الملف: text/html
اللغة: English
تدمد: 0100-3984
DOI: 10.1590/0100-3984.2017.0011
URL الوصول: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842018000200102
Rights: info:eu-repo/semantics/openAccess
رقم الانضمام: edssci.S0100.39842018000200102
قاعدة البيانات: SciELO
الوصف
تدمد:01003984
DOI:10.1590/0100-3984.2017.0011