Electronic Resource

An accurate and time-efficient deep learning-based system for automated segmentation and reporting of cardiac magnetic resonance-detected ischemic scar

التفاصيل البيبلوغرافية
العنوان: An accurate and time-efficient deep learning-based system for automated segmentation and reporting of cardiac magnetic resonance-detected ischemic scar
المؤلفون: Papetti, D, Van Abeelen, K, Davies, R, Menè, R, Heilbron, F, Perelli, F, Artico, J, Seraphim, A, Moon, J, Parati, G, Xue, H, Kellman, P, Badano, L, Besozzi, D, Nobile, M, Torlasco, C, Papetti, Daniele M, Van Abeelen, Kirsten, Davies, Rhodri, Menè, Roberto, Heilbron, Francesca, Perelli, Francesco P, Artico, Jessica, Seraphim, Andreas, Moon, James C, Parati, Gianfranco, Xue, Hui, Kellman, Peter, Badano, Luigi, Besozzi, Daniela, Nobile, Marco S, Torlasco, Camilla
بيانات النشر: Elsevier Ireland Ltd. country:IE 2023
نوع الوثيقة: Electronic Resource
مستخلص: Background and objectives: Myocardial infarction scar (MIS) assessment by cardiac magnetic resonance provides prognostic information and guides patients’ clinical management. However, MIS segmentation is time-consuming and not performed routinely. This study presents a deep-learning-based computational workflow for the segmentation of left ventricular (LV) MIS, for the first time performed on state-of-the-art dark-blood late gadolinium enhancement (DB-LGE) images, and the computation of MIS transmurality and extent. Methods: DB-LGE short-axis images of consecutive patients with myocardial infarction were acquired at 1.5T in two centres between Jan 1, 2019, and June 1, 2021. Two convolutional neural network (CNN) models based on the U-Net architecture were trained to sequentially segment the LV and MIS, by processing an incoming series of DB-LGE images. A 5-fold cross-validation was performed to assess the performance of the models. Model outputs were compared respectively with manual (LV endo- and epicardial border) and semi-automated (MIS, 4-Standard Deviation technique) ground truth to assess the accuracy of the segmentation. An automated post-processing and reporting tool was developed, computing MIS extent (expressed as relative infarcted mass) and transmurality. Results: The dataset included 1355 DB-LGE short-axis images from 144 patients (MIS in 942 images). High performance (> 0.85) as measured by the Intersection over Union metric was obtained for both the LV and MIS segmentations on the training sets. The performance for both LV and MIS segmentations was 0.83 on the test sets. Compared to the 4-Standard Deviation segmentation technique, our system was five times quicker (<1 min versus 7 ± 3 min), and required minimal user interaction. Conclusions: Our solution successfully addresses different issues related to automatic MIS segmentation, including accuracy, time-effectiveness, and the automatic generation of a clinical report.
مصطلحات الفهرس: Cardiac magnetic resonance, Cardiovascular imaging, Deep learning, Image processing, Myocardial ischemic scar, MED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLARE, INF/01 - INFORMATICA, info:eu-repo/semantics/article
URL: https://hdl.handle.net/10281/413278
info:eu-repo/semantics/altIdentifier/pmid/36586175
info:eu-repo/semantics/altIdentifier/wos/WOS:000918700900001
volume:229
issue:February 2023
journal:COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE
الاتاحة: Open access content. Open access content
info:eu-repo/semantics/openAccess
ملاحظة: STAMPA
English
Other Numbers: ITBAO oai:boa.unimib.it:10281/413278
10.1016/j.cmpb.2022.107321
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85145261139
1383766225
المصدر المساهم: BICOCCA OPEN ARCH
From OAIster®, provided by the OCLC Cooperative.
رقم الانضمام: edsoai.on1383766225
قاعدة البيانات: OAIster