Academic Journal

High proportion and large value harmonic current influence on the magnetic field, loss and temperature distribution for ultrahigh voltage converter transformer

التفاصيل البيبلوغرافية
العنوان: High proportion and large value harmonic current influence on the magnetic field, loss and temperature distribution for ultrahigh voltage converter transformer
المؤلفون: Cong Liu, Jian Hao, Ruijin Liao, Fan Yang, Wenping Li, Zhiwei Li
المصدر: IET Electric Power Applications, Vol 18, Iss 2, Pp 208-225 (2024)
بيانات النشر: Wiley, 2024.
سنة النشر: 2024
مصطلحات موضوعية: DC transformers, finite element analysis, harmonic analysis, temperature distribution, Applications of electric power, TK4001-4102
الوصف: Abstract The temperature distribution of ultrahigh voltage (UHV) converter transformer is the key to its service life, allowable load and safe operation. The influence of a high‐proportion and large‐value harmonic current on the magnetic field, loss and temperature distribution of a UHV converter transformer is studied. A new calculation method is proposed to determine the winding temperature under the combined actions of multiple key factors. First, the skin effect of UHV converter transformer winding under high proportion and high current harmonics is analysed extensively. It is found that the increase of harmonic current frequency leads to exponential increase of winding loss and temperature by changing skin depth. Second, based on the superposition principle, a calculation method for winding loss considering harmonic current and different load rates is developed. The temperature distribution under different harmonic current frequencies and contents is obtained. The winding losses and temperature under different harmonic currents are quantified. Finally, a new calculation method is proposed for the converter transformer winding temperature, considering the combined actions of factors such as load rate, cooling oil inlet rate and temperature, harmonic current frequency and content. Experimental verification showed an error of only 0.58 K in the actual transformer hotspot temperature, confirming the effectiveness of this method. This method is of great significance for temperature control and safe operation of UHV converter transformers.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1751-8679
1751-8660
Relation: https://doaj.org/toc/1751-8660; https://doaj.org/toc/1751-8679
DOI: 10.1049/elp2.12382
URL الوصول: https://doaj.org/article/cf61d49fbef946d1a6f590c8cfd68aca
رقم الانضمام: edsdoj.f61d49fbef946d1a6f590c8cfd68aca
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:17518679
17518660
DOI:10.1049/elp2.12382