Academic Journal

Application of an LC–MS/MS method for the analysis of amlodipine, valsartan and hydrochlorothiazide in polypill for a bioequivalence study

التفاصيل البيبلوغرافية
العنوان: Application of an LC–MS/MS method for the analysis of amlodipine, valsartan and hydrochlorothiazide in polypill for a bioequivalence study
المؤلفون: Jaivik V. Shah, Jignesh M. Parekh, Priyanka A. Shah, Priya V. Shah, Mallika Sanyal, Pranav S. Shrivastav
المصدر: Journal of Pharmaceutical Analysis, Vol 7, Iss 5, Pp 309-316 (2017)
بيانات النشر: Elsevier, 2017.
سنة النشر: 2017
المجموعة: LCC:Therapeutics. Pharmacology
مصطلحات موضوعية: Amlodipine, Valsartan, Hydrochlorothiazide, LC–MS/MS, Polypill, Bioequivalence, Therapeutics. Pharmacology, RM1-950
الوصف: A sensitive and selective method has been proposed for the simultaneous determination of amlodipine (AML), valsartan (VAL) and hydrochlorothiazide (HCTZ) in human plasma by liquid chromatography–tandem mass spectrometry (LC–MS/MS). The analytes and their deuterated analogs were quantitatively extracted from 100 µL human plasma by solid phase extraction on Oasis HLB cartridges. The chromatographic separation of the analytes was achieved on a Chromolith RP18e (100 mm × 4.6 mm) analytical column within 2.5 min. The resolution factor between AML and VAL, AML and HCTZ, and VAL and HCTZ was 2.9, 1.5 and 1.4, respectively, under isocratic conditions. The method was validated over a dynamic concentration range of 0.02–20.0 ng/mL for AML, 5.00–10,000 ng/mL for VAL and 0.20–200 ng/mL for HCTZ. Ion-suppression/enhancement effects were investigated by post-column infusion technique. The mean IS-normalized matrix factors for AML, VAL and HCTZ were 0.992, 0.994 and 0.998, respectively. The intra-batch and inter-batch precision (% CV) across quality control levels was ≤ 5.56% and the recovery was in the range of 93.4%–99.6% for all the analytes. The method was successfully applied to a bioequivalence study of 5 mg AML + 160 mg VAL + 12.5 mg HCTZ tablet formulation (test and reference) in 18 healthy Indian males under fasting. The mean log-transformed ratios of Cmax, AUC0–120h and AUC0-inf and their 90% CIs were within 90.2%–102.1%. The assay reproducibility was demonstrated by reanalysis of 90 incurred samples.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2095-1779
Relation: http://www.sciencedirect.com/science/article/pii/S2095177917300679; https://doaj.org/toc/2095-1779
DOI: 10.1016/j.jpha.2017.06.001
URL الوصول: https://doaj.org/article/bfd2fe5e6a7f4425b928f44c362b8ec9
رقم الانضمام: edsdoj.bfd2fe5e6a7f4425b928f44c362b8ec9
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20951779
DOI:10.1016/j.jpha.2017.06.001