Academic Journal
The effect of varying thicknesses of mineral trioxide aggregate (MTA) and Biodentine as apical plugs on the fracture resistance of teeth with simulated open apices: a comparative in vitro study
العنوان: | The effect of varying thicknesses of mineral trioxide aggregate (MTA) and Biodentine as apical plugs on the fracture resistance of teeth with simulated open apices: a comparative in vitro study |
---|---|
المؤلفون: | Pankaj Panjwani, Kulvinder Banga, Jatin Atram, Dian Agustin Wahjuningrum, Alexander Maniangat Luke, Krishna Prasad Shetty, Ajinkya M. Pawar |
المصدر: | PeerJ, Vol 12, p e18691 (2024) |
بيانات النشر: | PeerJ Inc., 2024. |
سنة النشر: | 2024 |
المجموعة: | LCC:Medicine LCC:Biology (General) |
مصطلحات موضوعية: | MTA, Biodentine, Apical plug, Fracture resistance, Open apex, Medicine, Biology (General), QH301-705.5 |
الوصف: | Background This study evaluates the fracture resistance of apical plugs created from Biodentine and mineral trioxide aggregate (MTA) in thicknesses of 3 and 5 mm within simulated open apex tooth models. Methods Fifty human maxillary central incisors were obtained from a pool of freshly extracted teeth. In order to replicate open apices without cavity preparation, ten teeth in the control group received apical-to-coronal preparation with Peeso reamers. The remaining 40 teeth were randomly assigned to four experimental groups and received either 3 or 5 mm Biodentine or MTA apical plugs. Results The mean fracture loads observed in this study were as follows: control group, 431.48 N (±34.55); 3 mm MTA, 774.88 N (±62.74); 5 mm MTA, 752.65 N (±73.79); 3 mm Biodentine, 918.25 N (±59.09); and 5 mm Biodentine, 903.42 N (±24.48). Specifically, teeth in the Biodentine group demonstrated considerably stronger fracture resistance compared to those in the MTA group (p < 0.001). However, no significant differences were observed between the 3 and 5 mm thicknesses (MTA: p = 0.98, Biodentine: p = 0.99), suggesting that plug thickness did not affect fracture resistance within both groups. Conclusion Biodentine apical plugs provided the highest fracture resistance among the materials, regardless of thickness. |
نوع الوثيقة: | article |
وصف الملف: | electronic resource |
اللغة: | English |
تدمد: | 2167-8359 |
Relation: | https://peerj.com/articles/18691.pdf; https://peerj.com/articles/18691/; https://doaj.org/toc/2167-8359 |
DOI: | 10.7717/peerj.18691 |
URL الوصول: | https://doaj.org/article/b60810860a984186b19306b934d79ba3 |
رقم الانضمام: | edsdoj.b60810860a984186b19306b934d79ba3 |
قاعدة البيانات: | Directory of Open Access Journals |
تدمد: | 21678359 |
---|---|
DOI: | 10.7717/peerj.18691 |