التفاصيل البيبلوغرافية
العنوان: |
High-Efficiency Circularly Polarized Phased Array Based on 5 μm-Thick Nematic Liquid Crystals: Design, Over-The-Air Calibration, and Experimental Validation |
المؤلفون: |
Xin Yu Wu, Fengshuo Wan, Hongyuan Feng, Shichao Jin, Chong Guo, Yu Wei, Dunge Liu, Yuqian Yang, Longzhu Cai, Zhi Hao Jiang, Wei Hong |
المصدر: |
Engineering, Vol 32, Iss , Pp 69-81 (2024) |
بيانات النشر: |
Elsevier, 2024. |
سنة النشر: |
2024 |
المجموعة: |
LCC:Engineering (General). Civil engineering (General) |
مصطلحات موضوعية: |
Circularly polarized, Liquid crystal, Liquid-crystal based phased array (LCPA), Phase shifter, Over-the-air (OTA) calibration, Engineering (General). Civil engineering (General), TA1-2040 |
الوصف: |
This paper presents a systematic investigation and demonstration of a K-band circularly polarized liquid-crystal-based phased array (LCPA), including the design, over-the-air (OTA) in-array calibration, and experimental validation. The LCPA contains 16 phase-shifting radiating channels, each consisting of a circularly polarized stacked patch antenna and a liquid-crystal-based phase shifter (LCPS) based on a loaded differential line structure. Thanks to its slow-wave properties, the LCPS exhibits a maximum phase-shifting range of more than 360° with a figure of merit of 78.3(° )·dB−1 based on a liquid crystal layer with a thickness of only 5 μm. Furthermore, an automatic OTA calibration based on a state ergodic method is proposed, which enables the extraction of the phase–voltage curve of every individual LCPA channel. The proposed LCPA is manufactured and characterized with a total profile of only 1.76 mm, experimentally demonstrating a scanned circularly polarized beam from −40° to +40° with a measured peak gain of 12.5 dBic and a scanning loss of less than 2.5 dB. The bandwidth of the LCPA, which satisfies the requirements of port reflection (|S11|) < −15 dB, an axial ratio (AR) < 3 dB, beam squinting < 3°, and a gain variation < 2.2 dB, spans from 25.5 to 26.0 GHz. The total efficiency is about 34%, which represents a new state of the art. The use of the demonstrated low-profile LCPA to support circularly polarized scanning beams, along with the systematic design and calibration methodology, holds potential promise for a variety of millimeter-wave applications. |
نوع الوثيقة: |
article |
وصف الملف: |
electronic resource |
اللغة: |
English |
تدمد: |
2095-8099 |
Relation: |
http://www.sciencedirect.com/science/article/pii/S209580992300423X; https://doaj.org/toc/2095-8099 |
DOI: |
10.1016/j.eng.2023.08.013 |
URL الوصول: |
https://doaj.org/article/b19fdc4afec240e7bbdba16cc88b519a |
رقم الانضمام: |
edsdoj.b19fdc4afec240e7bbdba16cc88b519a |
قاعدة البيانات: |