Academic Journal

A Polydopamine-Coated Gold Nanoparticles Quenching Quantum Dots-Based Dual-Readout Lateral Flow Immunoassay for Sensitive Detection of Carbendazim in Agriproducts

التفاصيل البيبلوغرافية
العنوان: A Polydopamine-Coated Gold Nanoparticles Quenching Quantum Dots-Based Dual-Readout Lateral Flow Immunoassay for Sensitive Detection of Carbendazim in Agriproducts
المؤلفون: Xinxin Mao, Yulong Wang, Lan Jiang, Hanxiaoya Zhang, Yun Zhao, Pengyan Liu, Juanjuan Liu, Bruce D. Hammock, Cunzheng Zhang
المصدر: Biosensors, Vol 12, Iss 2, p 83 (2022)
بيانات النشر: MDPI AG, 2022.
سنة النشر: 2022
المجموعة: LCC:Biotechnology
مصطلحات موضوعية: dual-readout, polydopamine, ZnCdSe/ZnS QDs, carbendazim, lateral flow immunoassay, Biotechnology, TP248.13-248.65
الوصف: In this study, a fluorometric and colorimetric dual-readout lateral flow immunoassay (LFIA) using antibody functionalized polydopamine-coated gold nanoparticles (Au@PDAs) as a probe was developed for the detection of carbendazim (CBD). Colloidal gold nanoparticles (AuNPs) were coated with polydopamines (PDA) by the oxidation of dopamine to synthesize Au@PDA nanoparticles. The Au@PDA nanoparticles mediated ZnCdSe/ZnS quantum dots (QDs) fluorescence quenching and recovery, resulting in a reverse fluorescence enhancement detection format of CBD. The CBD detection was obtained by the competition between the CBD and the immobilized antigen for Au@PDAs labelled antibody binding, resulting in a significant fluorescence increase and colorimetry decrease corresponded to the concentration of CBD. Dual readout modes were incorporated into the LFIA using the colorimetry signal under natural light and the fluorescence signal under UV light. The cut-off value in the mode of the colorimetric signal and fluorometric signal for CBD detection was 0.5 μg/mL and 0.0156 μg/mL, respectively. The sensitivity of LFIA of the fluorescence mode was 32 times higher than that of the colorimetry mode. There was negligible cross reactivity obtained by using LFIA for the determination of thiabendazole, benomyl, thiophanate-methyl, and thiophanate-ethyl. Consistent and satisfactory results have been achieved by comparing the results of Au@PDAs-QDs-LFIA and liquid chromatography-tandem mass spectrometry (LC—MS/MS) testing spiked cucumber and strawberry samples, indicating good reliability of the Au@PDAs-QDs-LFIA.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2079-6374
Relation: https://www.mdpi.com/2079-6374/12/2/83; https://doaj.org/toc/2079-6374
DOI: 10.3390/bios12020083
URL الوصول: https://doaj.org/article/99cce2fc6ce94a00b3c3c9365df5bba7
رقم الانضمام: edsdoj.99cce2fc6ce94a00b3c3c9365df5bba7
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20796374
DOI:10.3390/bios12020083