Academic Journal

Three-dimensional morphological analysis of the femoral neck torsion angle—an anatomical study

التفاصيل البيبلوغرافية
العنوان: Three-dimensional morphological analysis of the femoral neck torsion angle—an anatomical study
المؤلفون: Ru-Yi Zhang, Xiu-Yun Su, Jing-Xin Zhao, Jian-Tao Li, Li-Cheng Zhang, Pei-Fu Tang
المصدر: Journal of Orthopaedic Surgery and Research, Vol 15, Iss 1, Pp 1-8 (2020)
بيانات النشر: BMC, 2020.
سنة النشر: 2020
المجموعة: LCC:Orthopedic surgery
LCC:Diseases of the musculoskeletal system
مصطلحات موضوعية: Femoral neck torsion angle (FNTA), Femoral neck isthmus (FNI), Femoral neck basilar part (FNB), Coronal plane of the proximal femur, Morphology, Orthopedic surgery, RD701-811, Diseases of the musculoskeletal system, RC925-935
الوصف: Abstract Background The femoral neck torsion angle (FNTA) is an important but often neglected parameter in assessments of the anatomical morphology of the femoral neck, which is often confused with the femoral neck anteversion angle (FNAA) in the current literature. Currently, the measurement methods reported in the literature all adopt the naked eye or two-dimensional (2D) visualization method, and the measurement parameters and details are not clearly defined. The objection of this research was to provide a reliable 3D method for determining the femoral neck axis, to improve the measurement method of the FNTA, and to analyze the anatomical and clinical significance of the results. Methods Computed tomography (CT) data of 200 patients who received a lower extremity CT angiography examination were selected, and the bilateral femurs were reconstructed with three dimensional CT (3D CT). First, the 3D axis of the femoral neck was built. Second, the long axis of the cross section the femoral neck isthmus (FNI) and femoral neck basilar part (FNB) were confirmed by the “inertia axes” method, and the plane consisting of the long axis of the cross-section and the center of the femoral head was defined as the long axial plane. Third, the coronal plane of the proximal femur was determined through the long axis of the proximal femur and the femoral coronal. Finally, the FNTAs (the angles between the long axial planes and the coronal plane of the proximal femur) of FNI and FNB were measured. The size of FNTA was compared between the sexes and sides and different locations, the correlation between the parameters and age, height, and weight were evaluated. Results The difference in FNTA was statistically significant between the isthmus and the basilar part (isthmus 30.58 ± 8.90° vs. basilar part 23.79 ± 3.98°; p < 0.01). Significant difference in the FNTA was observed between the sexes (males 31.99 ± 9.25° vs. females 27.49 ± 7.19°; p < 0.01). The increase in FNTA from the basilar part to the isthmus was 6.79 ± 8.06°, and the male (7.87 ± 8.57°) was greater than the female (4.44 ± 6.23°, p < 0.01). However, no significant difference in the values was observed between sides. Height exerted the greatest effect on the FNTA according to the correlation analysis (r = 0.255, p< 0.001). Conclusions This study found a reliable 3D method for the determination of the femoral neck axis improved the measurement method of the FTNTA and made it more accurate and repeatable. The results provided a methodological basis and theoretical support for the research and development of internal fixation device for femoral neck fracture and the spatial configuration of implants in treatment. And the optimal opening point of the femoral medullary cavity was recommended to locate at the posterior position of the top of the femoral neck cross-section during hip replacement.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1749-799X
Relation: http://link.springer.com/article/10.1186/s13018-020-01712-8; https://doaj.org/toc/1749-799X
DOI: 10.1186/s13018-020-01712-8
URL الوصول: https://doaj.org/article/8761c0b695bb4639a3f32f1f238be728
رقم الانضمام: edsdoj.8761c0b695bb4639a3f32f1f238be728
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:1749799X
DOI:10.1186/s13018-020-01712-8