Academic Journal

Comparison of variability in diameter and taper of gutta percha cones of different brands using Stereomicroscopy and Digital Micrometer

التفاصيل البيبلوغرافية
العنوان: Comparison of variability in diameter and taper of gutta percha cones of different brands using Stereomicroscopy and Digital Micrometer
المؤلفون: N. Mishra, K. Magwa, M. Agarwal, M. P. Singh, S. Singh, S. Thakur
المصدر: Эндодонтия Today, Vol 19, Iss 2, Pp 90-94 (2021)
بيانات النشر: LLC "Endo Press", 2021.
سنة النشر: 2021
المجموعة: LCC:Dentistry
مصطلحات موضوعية: obturation, diameter variation, endodontics, gutta percha, taper, Dentistry, RK1-715
الوصف: Aim: Variations in cone tip diameter while obturation can lead to premature binding, extrusion, or poor adaptability of GP to the canal walls and promotes microleakage and ultimately endodontic failure. The purpose of this investigation was to measure the variability from the listed cone tip diameter and taper of size #25, 0.06 taper GP cones from three different brands with the help of stereomicroscope and digital micrometer.Materials and methods: 45 GP points (N = 45) of Size #25 with an 0.06 taper from three different brands were divided into three groups: Group A – Diadent Group B – K3 and Group C Pro- Taper Next. Each group have 15 GP (n = 15). The diameters (D0 and D3), tapers were measured according to the ANSI/ADA Specification No. 78 using stereomicroscope (accuracy of 0.001mm) and digital micrometer. Kruskall Wallis test was to detect any significant differences between two or more groups and Mann Whitney U test for pairwise comparison. p value < 0.05 were considered as statistically significant.Results: On comparing there was significant variability within the three brands using stereomicroscopy, the standard values for D0 diameter which was 0.25 ± 0.23, Protaper Next GP cones was the similar to the standardized values compared to Diadent and K3 GP cones which were significantly different from the standard values. On comparing diameter variation at D3, Protaper Next, 0.043 ± 0.018 was once again similar to its manufacturer standard values of 0.43 ± 0.022. Diadent showed mild variation with D3 Diameter of 0.44 ± 0.017 and K3 was significantly different from the standard values K3 was 0.41 ± 0.018.Conclusions: The results of the current study indicate significant variability between GP cone brands for both diameter and taper. However, the high standard deviation values associated with most of the diameter and taper differences from manufacturer’s nominal values also suggests high variability within individual brands.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: Russian
تدمد: 1683-2981
1726-7242
Relation: https://www.endodont.ru/jour/article/view/984; https://doaj.org/toc/1683-2981; https://doaj.org/toc/1726-7242
DOI: 10.36377/1683-2981-2021-19-2-90-94
URL الوصول: https://doaj.org/article/8220b0cdbc1c461a99da637edfc807c4
رقم الانضمام: edsdoj.8220b0cdbc1c461a99da637edfc807c4
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:16832981
17267242
DOI:10.36377/1683-2981-2021-19-2-90-94