Academic Journal
Gold marker displacement due to needle insertion during HDR-brachytherapy for treatment of prostate cancer: A prospective cone beam computed tomography and kilovoltage on-board imaging (kV-OBI) study
العنوان: | Gold marker displacement due to needle insertion during HDR-brachytherapy for treatment of prostate cancer: A prospective cone beam computed tomography and kilovoltage on-board imaging (kV-OBI) study |
---|---|
المؤلفون: | Herrmann Markus KA, Kertesz Tereza, Gsänger Tammo, Bloch Eugen, Pollul Gerhard, Bouabdallaoui Mohamed, Strauss Arne, Herrmann Mareike, Christiansen Hans, Wolff Hendrik A, Hess Clemens F, Hille Andrea |
المصدر: | Radiation Oncology, Vol 7, Iss 1, p 24 (2012) |
بيانات النشر: | BMC, 2012. |
سنة النشر: | 2012 |
المجموعة: | LCC:Medical physics. Medical radiology. Nuclear medicine LCC:Neoplasms. Tumors. Oncology. Including cancer and carcinogens |
مصطلحات موضوعية: | Prostate cancer, HDR-brachytherapy, Gold markers, Conformal radiotherapy, Intensity modulated radiotherapy, Medical physics. Medical radiology. Nuclear medicine, R895-920, Neoplasms. Tumors. Oncology. Including cancer and carcinogens, RC254-282 |
الوصف: | Abstract Purpose To evaluate gold marker displacement due to needle insertion during HDR-brachytherapy for therapy of prostate cancer. Patients and methods 18 patients entered into this prospective evaluation. Three gold markers were implanted into the prostate during the first HDR-brachytherapy procedure after the irradiation was administered. Three days after marker implantation all patients had a CT-scan for planning purpose of the percutaneous irradiation. Marker localization was defined on the digitally-reconstructed-radiographs (DRR) for daily (VMAT technique) or weekly (IMRT) set-up error correction. Percutaneous therapy started one week after first HDR-brachytherapy. After the second HDR-brachytherapy, two weeks after first HDR-brachtherapy, a cone-beam CT-scan was done to evaluate marker displacement due to needle insertion. In case of marker displacement, the actual positions of the gold markers were adjusted on the DRR. Results The value of the gold marker displacement due to the second HDR-brachytherapy was analyzed in all patients and for each gold marker by comparison of the marker positions in the prostate after soft tissue registration of the prostate of the CT-scans prior the first and second HDR-brachytherapy. The maximum deviation was 5 mm, 7 mm and 12 mm for the anterior-posterior, lateral and superior-inferior direction. At least one marker in each patient showed a significant displacement and therefore new marker positions were adjusted on the DRRs for the ongoing percutaneous therapy. Conclusions Needle insertion in the prostate due to HDR-brachytherapy can lead to gold marker displacements. Therefore, it is necessary to verify the actual position of markers after the second HDR-brachytherapy. In case of significant deviations, a new DRR with the adjusted marker positions should be generated for precise positioning during the ongoing percutaneous irradiation. |
نوع الوثيقة: | article |
وصف الملف: | electronic resource |
اللغة: | English |
تدمد: | 1748-717X |
Relation: | http://www.ro-journal.com/content/7/1/24; https://doaj.org/toc/1748-717X |
DOI: | 10.1186/1748-717X-7-24 |
URL الوصول: | https://doaj.org/article/81319a71589d437eaf9e89ce1766dea4 |
رقم الانضمام: | edsdoj.81319a71589d437eaf9e89ce1766dea4 |
قاعدة البيانات: | Directory of Open Access Journals |
تدمد: | 1748717X |
---|---|
DOI: | 10.1186/1748-717X-7-24 |