Academic Journal
Is High Temporal Resolution Achievable for Paediatric Cardiac Acquisitions during Several Heart Beats? Illustration with Cardiac Phase Contrast Cine-MRI.
العنوان: | Is High Temporal Resolution Achievable for Paediatric Cardiac Acquisitions during Several Heart Beats? Illustration with Cardiac Phase Contrast Cine-MRI. |
---|---|
المؤلفون: | Laurent Bonnemains, Freddy Odille, Christophe Meyer, Gabriella Hossu, Jacques Felblinger, Pierre-André Vuissoz |
المصدر: | PLoS ONE, Vol 10, Iss 11, p e0143744 (2015) |
بيانات النشر: | Public Library of Science (PLoS), 2015. |
سنة النشر: | 2015 |
المجموعة: | LCC:Medicine LCC:Science |
مصطلحات موضوعية: | Medicine, Science |
الوصف: | During paediatric cardiac Cine-MRI, data acquired during cycles of different lengths must be combined. Most of the time, Feinstein's model is used to project multiple cardiac cycles of variable lengths into a mean cycle.To assess the effect of Feinstein projection on temporal resolution of Cine-MRI.1/The temporal errors during Feinstein's projection were computed in 306 cardiac cycles fully characterized by tissue Doppler imaging with 6-phase analysis (from a population of 7 children and young adults). 2/The effects of these temporal errors on tissue velocities were assessed by simulating typical tissue phase mapping acquisitions and reconstructions. 3/Myocardial velocities curves, extracted from high-resolution phase-contrast cine images, were compared for the 6 volunteers with lowest and highest heart rate variability, within a population of 36 young adults.1/The mean of temporal misalignments was 30 ms over the cardiac cycle but reached 60 ms during early diastole. 2/During phase contrast MRI simulation, early diastole velocity peaks were diminished by 6.1 cm/s leading to virtual disappearance of isovolumic relaxation peaks. 3/The smoothing and erasing of isovolumic relaxation peaks was confirmed on tissue phase mapping velocity curves, between subjects with low and high heart rate variability (p = 0.05).Feinstein cardiac model creates temporal misalignments that impair high temporal resolution phase contrast cine imaging when beat-to-beat heart rate is changing. |
نوع الوثيقة: | article |
وصف الملف: | electronic resource |
اللغة: | English |
تدمد: | 1932-6203 |
Relation: | http://europepmc.org/articles/PMC4658039?pdf=render; https://doaj.org/toc/1932-6203 |
DOI: | 10.1371/journal.pone.0143744 |
URL الوصول: | https://doaj.org/article/8106699d8b9240c78fe2e20273fbf280 |
رقم الانضمام: | edsdoj.8106699d8b9240c78fe2e20273fbf280 |
قاعدة البيانات: | Directory of Open Access Journals |
تدمد: | 19326203 |
---|---|
DOI: | 10.1371/journal.pone.0143744 |