Academic Journal

Evaluation of Filtering Bleb Function after Trabeculectomy with Mitomycin C Using Biomicroscopy, Anterior Segment Optical Coherence Tomography and In Vivo Confocal Microscopy

التفاصيل البيبلوغرافية
العنوان: Evaluation of Filtering Bleb Function after Trabeculectomy with Mitomycin C Using Biomicroscopy, Anterior Segment Optical Coherence Tomography and In Vivo Confocal Microscopy
المؤلفون: Suzan Güven Yılmaz, Cumali Değirmenci, Melis Palamar, Ayşe Yağcı
المصدر: Türk Oftalmoloji Dergisi, Vol 45, Iss 4, Pp 132-137 (2015)
بيانات النشر: Galenos Yayinevi, 2015.
سنة النشر: 2015
المجموعة: LCC:Medicine
LCC:Ophthalmology
مصطلحات موضوعية: Bleb, biomicroscopy, anterior segment optical coherence tomography, in vivo confocal microscopy, Medicine, Ophthalmology, RE1-994
الوصف: Objectives: To analyze and assess compatibility of trabeculectomy filtering bleb characteristics and appearances using biomicroscopy, anterior segment optical coherence tomography (AS-OCT) and in vivo confocal microscopy (IVCM). Materials and Methods: Twenty-eight eyes of 28 patients who underwent glaucoma filtering surgery with mitomycin C in our clinic between 2009 and 2013 were evaluated. Morphological appearances of the blebs on slit-lamp biomicroscopy were defined according to the Moorfields bleb classification system. For the internal tissue assessment of blebs, AS-OCT and IVCM were performed. Bleb biometric parameters such as length, height and bleb wall thickness were assessed by AS-OCT; conjunctival epithelial-stromal cyst, structural network of conjunctival stroma and vascularisation were examined with IVCM. The relation between biomicroscopic morphological staging and bleb characteristics detected on AS-OCT and IVCM were assessed. Results: The mean age of the 28 patients (16 male, 12 female) was 57.2±15.9 (19 to 79) years. The mean time elapsed between surgery and examination was 29.2±19.2 (6 to 68) months. According to biomicroscopic appearance, 17 (60.7%) blebs were functional (13 diffuse, 4 microcystic), whereas 11 (39.3%) blebs were non-functional (9 flat, 2 encapsulated). In the comparison of non-functional and functional blebs, functional blebs were found to be superior in terms of biometric parameters on AS-OCT assessment (p
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
Turkish
تدمد: 1300-0659
2147-2661
Relation: http://www.oftalmoloji.org/article_9128/Evaluation-Of-Filtering-Bleb-Function-After-Trabeculectomy-With-Mitomycin-C-Using-Biomicroscopy-Anterior-Segment-Optical-Coherence-Tomography-And-In-Vivo-Confocal-Microscopy; https://doaj.org/toc/1300-0659; https://doaj.org/toc/2147-2661
DOI: 10.4274/tjo.29052
URL الوصول: https://doaj.org/article/7e9d6e6ef86e4ac4aff50d07804532c9
رقم الانضمام: edsdoj.7e9d6e6ef86e4ac4aff50d07804532c9
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:13000659
21472661
DOI:10.4274/tjo.29052