Academic Journal

Effects of motion direction and power of Er,Cr:YSGG laser on pull-out bond strength of fiber post to root dentin in endodontically-treated single-canal premolar teeth

التفاصيل البيبلوغرافية
العنوان: Effects of motion direction and power of Er,Cr:YSGG laser on pull-out bond strength of fiber post to root dentin in endodontically-treated single-canal premolar teeth
المؤلفون: Loghman Rezaei-Soufi, Leili Tapak, Mahsa Forouzande, Reza Fekrazad
المصدر: Biomaterials Research, Vol 23, Iss 1, Pp 1-8 (2019)
بيانات النشر: American Association for the Advancement of Science (AAAS), 2019.
سنة النشر: 2019
المجموعة: LCC:Medical technology
مصطلحات موضوعية: Laser, Fiber post, Surface treatment, Medical technology, R855-855.5
الوصف: Abstract Background Inadequate retention and gradual debonding of intracanal post from root dentin is a major cause of failure of endodontically treated teeth restored with fiber post. Main body This study aimed to assess the effect of surface treatment of quartz fiber posts with different powers and motion directions of Er,Cr:YSGG laser on their pull-out bond strength to root dentin in endodontically treated premolar teeth. In this study, 105 fiber posts were divided into 7 groups according to their surface treatment with different powers of Er,Cr:YSGG laser at 2780 nm wavelength, 20 Hz frequency and 150 μs pulse duration in circumferential (C) or longitudinal (L) motion directions: Control group (no treatment), 0.5 W laser in longitudinally (L0.5), 1.0 W laser in longitudinally (L1), 1.5 W laser in longitudinally (L1.5), 0.5 W laser in circumferentially (C0.5), 1.0 W laser in circumferentially (C1) and 1.5 W laser in circumferentially (C1.5). After cementation, pull-out bond strength was measured in Newton (N). Each sample was inspected under a stereomicroscope at × 25 magnification to determine the mode of failure. Two samples of each group were inspected under a scanning electron microscope (SEM). Data were analyzed using two-way ANOVA and Tukey’s test with significant level of 0.05. The pull-out bond strength of 0.5 W groups had significant differences with the control group (P = 0.009). The bond strength of 1.0 W and 1.5 W groups were not significantly different (P = 0.630) but were higher than the control and 0.5 W groups (P
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2055-7124
Relation: http://link.springer.com/article/10.1186/s40824-019-0165-y; https://doaj.org/toc/2055-7124
DOI: 10.1186/s40824-019-0165-y
URL الوصول: https://doaj.org/article/a79c430e9c5a423a9e04d3bc520f19c5
رقم الانضمام: edsdoj.79c430e9c5a423a9e04d3bc520f19c5
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20557124
DOI:10.1186/s40824-019-0165-y