Academic Journal

Convective Heat Exchange of Single-Row Bundles from Tubes with Rolled Aluminum Fins of Various Height at a Low Values of the Reynolds Number

التفاصيل البيبلوغرافية
العنوان: Convective Heat Exchange of Single-Row Bundles from Tubes with Rolled Aluminum Fins of Various Height at a Low Values of the Reynolds Number
المؤلفون: A. B. Sukhotski, Е. S. Danil’chik
المصدر: Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika, Vol 64, Iss 4, Pp 336-348 (2021)
بيانات النشر: Belarusian National Technical University, 2021.
سنة النشر: 2021
المجموعة: LCC:Hydraulic engineering
LCC:Engineering (General). Civil engineering (General)
مصطلحات موضوعية: bimetallic finned tube, single-row tube heat exchanger, dimensional and metalintensive characteristics, exhaust shaft, low reynolds numbers, nusselts number, the criteria equation of a heat transfer, Hydraulic engineering, TC1-978, Engineering (General). Civil engineering (General), TA1-2040
الوصف: The experimental study of the heat flow intensity of a single-row horizontal air-cooled tubular bundle of heat exchanger with spiral aluminum rolling fins at low Reynolds numbers (Re < 2000) is performed. The geometrical dimensions of the bimetallic finned tubes of the bundle, the following: the outer diameter of the fins d = 56.0 mm; the diameter of the tube at the base d0 = 26.8 mm; fin height h = 14.6 mm; pitch of fins s = 2.5 mm; the average fin thickness Δ = 0.5 mm; the coefficient of finned tubes φ = 19.3; heat transfer length l = 300 mm. The outer diameter of the load-bearing steel tube dн = 25 mm; wall thickness d = 2 mm. The research was carried out by the method of full thermal modeling at a specially designed experimental stand with electric heating of tubes and an exhaust shaft installed above the bundle. The air flow rate through the bundle was regulated by changing the height and cross-sectional area of the exhaust shaft. Calibration experiments were carried out and confirmed the reliability of the data obtained. Then the fins were sanded so to form new types of tubes, which were arranged in a single-row six-tube bundle with a constant relative cross-step σ1 = S1/d = 1.14 = const, and the thermal studies were repeated. As a result, a generalized criterion equation for heat transfer of a finned horizontal single-row bundle at small Reynolds numbers for various heights of the tube finning h = 0-14.6 mm was obtained. The effective height of the tube finning (h = 8 mm) for a single-row horizontal bundle was determined by dimensional and metal-intensive criteria.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: Russian
تدمد: 1029-7448
2414-0341
Relation: https://energy.bntu.by/jour/article/view/2085; https://doaj.org/toc/1029-7448; https://doaj.org/toc/2414-0341
DOI: 10.21122/1029-7448-2021-64-4-336-348
URL الوصول: https://doaj.org/article/6d456125da2e4cc1b70bd2a790de3330
رقم الانضمام: edsdoj.6d456125da2e4cc1b70bd2a790de3330
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:10297448
24140341
DOI:10.21122/1029-7448-2021-64-4-336-348