Academic Journal

Identification of a small thrombus in the left ventricle identified on iodine maps derived from dual-source photon-counting detector CT

التفاصيل البيبلوغرافية
العنوان: Identification of a small thrombus in the left ventricle identified on iodine maps derived from dual-source photon-counting detector CT
المؤلفون: Masaya Kisohara, MD, PhD, Nobuo Kitera, MSc, Toshihide Itoh, PhD, Kazuma Murai, MD, Akio Hiwatashi, MD, PhD, Tatsuya Kawai, MD, PhD
المصدر: Radiology Case Reports, Vol 19, Iss 4, Pp 1404-1408 (2024)
بيانات النشر: Elsevier, 2024.
سنة النشر: 2024
المجموعة: LCC:Medical physics. Medical radiology. Nuclear medicine
مصطلحات موضوعية: Left ventricular thrombus, Iodine maps, Coronary CT angiography, Transthoracic echocardiographyce, Medical physics. Medical radiology. Nuclear medicine, R895-920
الوصف: Transthoracic echocardiography is the main imaging modality to diagnose left ventricular thrombus (LVT), but its efficacy in certain cases is suboptimal. We report a patient in whom an LVT, initially unidentified by transthoracic echocardiography, was successfully diagnosed with iodine maps derived from dual-source photon-counting detector CT (DS-PCD-CT). The 64-year-old male was admitted to our institution following myocardial infarction. Although TTE failed to detect this small LVT, iodine maps derived from CT angiography (which was conducted to evaluate the coronary artery stenosis) revealed its presence. Iodine maps derived from DS-PCD-CT collecting data with high temporal resolution are beneficial to diagnose LVTs.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1930-0433
Relation: http://www.sciencedirect.com/science/article/pii/S1930043324000207; https://doaj.org/toc/1930-0433
DOI: 10.1016/j.radcr.2024.01.020
URL الوصول: https://doaj.org/article/c6c71e2c66fc404a8f9a2ee0e53bb7e3
رقم الانضمام: edsdoj.6c71e2c66fc404a8f9a2ee0e53bb7e3
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:19300433
DOI:10.1016/j.radcr.2024.01.020