Waterjet submucosal dissection of porcine esophagus with the HybridKnife and ERBEJET 2 system: a pilot study

التفاصيل البيبلوغرافية
العنوان: Waterjet submucosal dissection of porcine esophagus with the HybridKnife and ERBEJET 2 system: a pilot study
المؤلفون: Daisuke Akutsu, Hideo Suzuki, Toshiaki Narasaka, Masahiko Terasaki, Tsuyoshi Kaneko, Hirofumi Matsui, Yuji Mizokami, Ichinosuke Hyodo
المصدر: Endoscopy International Open, Vol 05, Iss 01, Pp E30-E34 (2017)
بيانات النشر: Georg Thieme Verlag KG, 2017.
سنة النشر: 2017
المجموعة: LCC:Diseases of the digestive system. Gastroenterology
مصطلحات موضوعية: Diseases of the digestive system. Gastroenterology, RC799-869
الوصف: Background and study aims Esophageal endoscopic submucosal dissection (ESD) is technically difficult because of narrow working spaces and ease of perforation due to the lack of serosa. HybridKnife is a recently developed ESD device that is combined with the high pressure waterjet ERBEJET 2 system to lift mucosa. We hypothesized that this waterjet could make submucosal dissection safer and studied this in porcine esophagus. Materials and methods Water pressures of 30 – 70 bar were tested to determine the appropriate pressure for waterjet ESD with HybridKnife (WJ-ESD) in one pig. WJ-ESD safety and completion were compared with those of conventional ESD using DualKnife (C-ESD) as a reference. Each of three virtual esophageal lesions in two pigs were resected alternatively using both methods from the lower to upper esophagus. For WJ-ESD, the submucosa, apart from hard fibrous tissues, was dissected using water pressure alone. Results Using 50 bar of water pressure resulted in the best balance between proper dissection and view-disturbing water backflow. The dissection speeds for the lower, middle, and upper esophagus were 0.2, 0.9, and 0.2 cm2/min in 50 bar WJ-ESD and 1.1, 0.5, and 1.0 cm2/min in C-ESD, respectively. Minor bleeding was frequent in WJ-ESD, but was easily stopped by electrocoagulation with the same needle. No perforation was observed in either procedure. Thermal damage to dissected tissues appeared mild, and the extent of muscle injury was lower for WJ-ESD (4, 6, and 8 %) compared with C-ESD (14, 16, and 7 %). Conclusions WJ-ESD could be completed safely for porcine esophagus with less damage to the muscle layer compared with C-ESD.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2364-3722
2196-9736
Relation: https://doaj.org/toc/2364-3722; https://doaj.org/toc/2196-9736
DOI: 10.1055/s-0042-122335
URL الوصول: https://doaj.org/article/688e4cdf9c6c4937b5166db74e468577
رقم الانضمام: edsdoj.688e4cdf9c6c4937b5166db74e468577
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:23643722
21969736
DOI:10.1055/s-0042-122335