Contactless Vital Sign Monitoring System for Heart and Respiratory Rate Measurements with Motion Compensation Using a Near-Infrared Time-of-Flight Camera
العنوان: | Contactless Vital Sign Monitoring System for Heart and Respiratory Rate Measurements with Motion Compensation Using a Near-Infrared Time-of-Flight Camera |
---|---|
المؤلفون: | Kaiwen Guo, Tianqu Zhai, Elton Pashollari, Christopher J. Varlamos, Aymaan Ahmed, Mohammed N. Islam |
المصدر: | Applied Sciences, Vol 11, Iss 22, p 10913 (2021) |
بيانات النشر: | MDPI AG, 2021. |
سنة النشر: | 2021 |
المجموعة: | LCC:Technology LCC:Engineering (General). Civil engineering (General) LCC:Biology (General) LCC:Physics LCC:Chemistry |
مصطلحات موضوعية: | time-of-flight, contactless physiological measurement, heart rate monitoring, motion artifacts compensation, Technology, Engineering (General). Civil engineering (General), TA1-2040, Biology (General), QH301-705.5, Physics, QC1-999, Chemistry, QD1-999 |
الوصف: | This study describes a contactless vital sign monitoring (CVSM) system capable of measuring heart rate (HR) and respiration rate (RR) using a low-power, indirect time-of-flight (ToF) camera. The system takes advantage of both the active infrared illumination as well as the additional depth information from the ToF camera to compensate for the motion-induced artifacts during the HR measurements. The depth information captures how the user is moving with respect to the camera and, therefore, can be used to differentiate where the intensity change in the raw signal is from the underlying heartbeat or motion. Moreover, from the depth information, the system can acquire respiration rate by directly measuring the motion of the chest wall during breathing. We also conducted a pilot human study using this system with 29 participants of different demographics such as age, gender, and skin color. Our study shows that with depth-based motion compensation, the success rate (system measurement within 10% of reference) of HR measurements increases to 75%, as compared to 35% when motion compensation is not used. The mean HR deviation from the reference also drops from 21 BPM to −6.25 BPM when we apply the depth-based motion compensation. In terms of the RR measurement, our system shows a mean deviation of 1.7 BPM from the reference measurement. The pilot human study shows the system performance is independent of skin color but weakly dependent on gender and age. |
نوع الوثيقة: | article |
وصف الملف: | electronic resource |
اللغة: | English |
تدمد: | 2076-3417 |
Relation: | https://www.mdpi.com/2076-3417/11/22/10913; https://doaj.org/toc/2076-3417 |
DOI: | 10.3390/app112210913 |
URL الوصول: | https://doaj.org/article/61c6f81db3e44113bf8341f04207b360 |
رقم الانضمام: | edsdoj.61c6f81db3e44113bf8341f04207b360 |
قاعدة البيانات: | Directory of Open Access Journals |
تدمد: | 20763417 |
---|---|
DOI: | 10.3390/app112210913 |