Rational design of non-convective zone of salt gradient solar pond considering turbidity and biological growth in water.

التفاصيل البيبلوغرافية
العنوان: Rational design of non-convective zone of salt gradient solar pond considering turbidity and biological growth in water.
المؤلفون: A. K. Saxena, S. Sugandhi, M. Hussain
المصدر: Environment Conservation Journal, Vol 8, Iss 3 (2007)
بيانات النشر: Action for Sustainable Efficacious Development and Awareness, 2007.
سنة النشر: 2007
المجموعة: LCC:Environmental sciences
مصطلحات موضوعية: Non Convective Zone, optimum size, salt gradient solar pond, stability, thermal performance, turbidity, Environmental sciences, GE1-350
الوصف: The optimum size of non-convective zone of a Salt Gradient Solar Pond is determined from the heat balance considerations of the storage zone. The equation governing heat flow in storage zone are simplified considering a linear heat flow through the storage zone to the upper convective zone.The radiation absorption in pond liqui d is estimated c onsideri ng the effect of various Environ mental parameters in pon d like turbidity and biological growth in it. This has made the analysis more confirming to the real work situation for a pond. The ambient parameter like temperature and radiation are accounted to vary hourly. One significant observation is that the influence of turbidity on pond’s performance is so drastic that at turbidity value higher than 0.8\NTU, the optimum Non-Convective Zone (NCZ) size is not obtained analytically.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 0972-3099
2278-5124
Relation: https://journal.environcj.in/index.php/ecj/article/view/2105; https://doaj.org/toc/0972-3099; https://doaj.org/toc/2278-5124
DOI: 10.36953/ECJ.2007.080318
URL الوصول: https://doaj.org/article/612874297e3149129fd58bd0b9b1a0e8
رقم الانضمام: edsdoj.612874297e3149129fd58bd0b9b1a0e8
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:09723099
22785124
DOI:10.36953/ECJ.2007.080318