Repeatability and reproducibility of multiparametric magnetic resonance imaging of the liver.

التفاصيل البيبلوغرافية
العنوان: Repeatability and reproducibility of multiparametric magnetic resonance imaging of the liver.
المؤلفون: Velicia Bachtiar, Matthew D Kelly, Henry R Wilman, Jaco Jacobs, Rexford Newbould, Catherine J Kelly, Michael L Gyngell, Katherine E Groves, Andy McKay, Amy H Herlihy, Carolina C Fernandes, Mark Halberstadt, Marion Maguire, Naomi Jayaratne, Sophia Linden, Stefan Neubauer, Rajarshi Banerjee
المصدر: PLoS ONE, Vol 14, Iss 4, p e0214921 (2019)
بيانات النشر: Public Library of Science (PLoS), 2019.
سنة النشر: 2019
المجموعة: LCC:Medicine
LCC:Science
مصطلحات موضوعية: Medicine, Science
الوصف: As the burden of liver disease reaches epidemic levels, there is a high unmet medical need to develop robust, accurate and reproducible non-invasive methods to quantify liver tissue characteristics for use in clinical development and ultimately in clinical practice. This prospective cross-sectional study systematically examines the repeatability and reproducibility of iron-corrected T1 (cT1), T2*, and hepatic proton density fat fraction (PDFF) quantification with multiparametric MRI across different field strengths, scanner manufacturers and models. 61 adult participants with mixed liver disease aetiology and those without any history of liver disease underwent multiparametric MRI on combinations of 5 scanner models from two manufacturers (Siemens and Philips) at different field strengths (1.5T and 3T). We report high repeatability and reproducibility across different field strengths, manufacturers, and scanner models in standardized cT1 (repeatability CoV: 1.7%, bias -7.5ms, 95% LoA of -53.6 ms to 38.5 ms; reproducibility CoV 3.3%, bias 6.5 ms, 95% LoA of -76.3 to 89.2 ms) and T2* (repeatability CoV: 5.5%, bias -0.18 ms, 95% LoA -5.41 to 5.05 ms; reproducibility CoV 6.6%, bias -1.7 ms, 95% LoA -6.61 to 3.15 ms) in human measurements. PDFF repeatability (0.8%) and reproducibility (0.75%) coefficients showed high precision of this metric. Similar precision was observed in phantom measurements. Inspection of the ICC model indicated that most of the variance in cT1 could be accounted for by study participants (ICC = 0.91), with minimal contribution from technical differences. We demonstrate that multiparametric MRI is a non-invasive, repeatable and reproducible method for quantifying liver tissue characteristics across manufacturers (Philips and Siemens) and field strengths (1.5T and 3T).
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1932-6203
Relation: https://doaj.org/toc/1932-6203
DOI: 10.1371/journal.pone.0214921
URL الوصول: https://doaj.org/article/5859963dc92b4a2bbff5136ebcfff637
رقم الانضمام: edsdoj.5859963dc92b4a2bbff5136ebcfff637
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:19326203
DOI:10.1371/journal.pone.0214921