Academic Journal

Development of paper-based microfluidic analytical device (μPAD) for the determination of paracetamol in water samples: Optimization using response surface methodology (RSM)

التفاصيل البيبلوغرافية
العنوان: Development of paper-based microfluidic analytical device (μPAD) for the determination of paracetamol in water samples: Optimization using response surface methodology (RSM)
المؤلفون: Nejat Mohammednur, Ahmed Hussen, Feleke Zewge
المصدر: Applied Water Science, Vol 14, Iss 12, Pp 1-11 (2024)
بيانات النشر: SpringerOpen, 2024.
سنة النشر: 2024
المجموعة: LCC:Water supply for domestic and industrial purposes
مصطلحات موضوعية: Beeswax screen printing, Colorimetric analysis, Paper-based microfluidic devices, Paracetamol, Response surface methodology, Water supply for domestic and industrial purposes, TD201-500
الوصف: Abstract Detecting and quantifying pharmaceutical compounds in various environmental matrices is complex and challenging. This difficulty stems from the trace levels at which these compounds are found and the lack of analytical methods that are rapid, cost-effective, and portable. To address these challenges, this study aimed to develop microfluidic paper-based analytical devices (μ-PADs) using beeswax screen printing for fabrication. Key parameters, including reaction time, concentration, reagent volume, and channel length, were optimized using response surface methodology. Under optimal conditions of 5 ppm sample concentration, 10 μL reagent volume, 10 min reaction time, and 2 cm channel length, the analytical performance of the μPAD was evaluated and compared with the standard UV–Vis spectrophotometry method. The microfluidic analytical device demonstrated detection limits at 0.03 μg/ml, compared to 0.01 μg/ml for the UV–Vis spectrophotometer. Although the sensitivity of µ-PADs in this study (0.03 μg/ml) is lower than that of UV–Vis (0.01 μg/ml), it represents an improvement over the previous µ-PAD report (1 μg/ml) on the same analytes. Both methods exhibited commendable precision, with a relative standard deviation below 2%. Additionally, recovery rates were acceptable and comparable, ranging from 86.8 to 99.6% for µ-PADs and 96.5–99% for UV–Vis. The analytical performance evaluation suggests that µPADs provide excellent sensitivity, precision, and accuracy for trace-level paracetamol analysis. A paired t-test further confirmed no statistically significant difference between the two methods, underscoring the promising potential of µ-PADs for trace-level paracetamol quantification in water samples without conventional analytical instruments.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2190-5487
2190-5495
Relation: https://doaj.org/toc/2190-5487; https://doaj.org/toc/2190-5495
DOI: 10.1007/s13201-024-02307-y
URL الوصول: https://doaj.org/article/57be2f80b6fb4412bd4c7bee54e73d4c
رقم الانضمام: edsdoj.57be2f80b6fb4412bd4c7bee54e73d4c
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:21905487
21905495
DOI:10.1007/s13201-024-02307-y