Academic Journal

Per-fraction positional and dosimetric performance of prone breast tangential radiotherapy on Halcyon™ linear accelerator assessed with daily rapid kilo-voltage cone beam computed tomography: a single-institution pilot study

التفاصيل البيبلوغرافية
العنوان: Per-fraction positional and dosimetric performance of prone breast tangential radiotherapy on Halcyon™ linear accelerator assessed with daily rapid kilo-voltage cone beam computed tomography: a single-institution pilot study
المؤلفون: Suk W. Yoon, Neil K. Taunk, Gary M. Freedman, Emily Hubley, Shannon O’Reilly, Boon- Keng K. Teo, Shibu Anamalayil, Lei Dong, Christopher Kennedy, Wei Zou, James M. Metz, Taoran Li
المصدر: Radiation Oncology, Vol 15, Iss 1, Pp 1-16 (2020)
بيانات النشر: BMC, 2020.
سنة النشر: 2020
المجموعة: LCC:Medical physics. Medical radiology. Nuclear medicine
LCC:Neoplasms. Tumors. Oncology. Including cancer and carcinogens
مصطلحات موضوعية: Whole breast radiation therapy, Tangential field radiotherapy, Adaptive replanning, O-ring linear accelerator, Daily CBCT, Medical physics. Medical radiology. Nuclear medicine, R895-920, Neoplasms. Tumors. Oncology. Including cancer and carcinogens, RC254-282
الوصف: Abstract Background This study investigates daily breast geometry and delivered dose to prone-positioned patients undergoing tangential whole breast radiation therapy (WBRT) on an O-ring linear accelerator with 6X flattening filter free mode (6X-FFF), planned with electronic compensation (ECOMP) method. Most practices rely on skin marks or daily planar image matching for prone breast WBRT. This system provides low dose daily CBCT, which was used to study daily robustness of delivered dose parameters for prone-positioned WBRT. Methods Eight patients treated with 16-fraction prone-breast WBRT were retrospectively studied. Planning CTs were deformed to daily CBCT to generate daily synthetic CTs, on which delivered dose distributions were calculated. A total of 8 × 16 = 128 synthetic CTs were generated. Consensus ASTRO definition was used to contour Breast PTV Eval for each daily deformed CT. Breast PTV Eval coverage (V90%) and hotspot (V105% and Dmax) were monitored daily to compare prescription dose with daily delivered dose. Various predictors including patient weight, breast width diameter (BWD), and Dice similarity coefficient (DSC) were fit into an analysis of covariance model predicting V90% and V105% deviation from prescribed (ΔV90%, ΔV105%). Statistical significance is indicated with asterisks (* for p
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1748-717X
Relation: http://link.springer.com/article/10.1186/s13014-020-01700-6; https://doaj.org/toc/1748-717X
DOI: 10.1186/s13014-020-01700-6
URL الوصول: https://doaj.org/article/52b92fc9fc8b42528409083957997083
رقم الانضمام: edsdoj.52b92fc9fc8b42528409083957997083
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:1748717X
DOI:10.1186/s13014-020-01700-6