Comparison between the falling head and the constant head permeability tests to assess the permeability coefficient of sustainable Pervious Concretes

التفاصيل البيبلوغرافية
العنوان: Comparison between the falling head and the constant head permeability tests to assess the permeability coefficient of sustainable Pervious Concretes
المؤلفون: Gersson F.B. Sandoval, Isaac Galobardes, Raquel S. Teixeira, Berenice M. Toralles
المصدر: Case Studies in Construction Materials, Vol 7, Iss C, Pp 317-328 (2017)
بيانات النشر: Elsevier, 2017.
سنة النشر: 2017
المجموعة: LCC:Materials of engineering and construction. Mechanics of materials
مصطلحات موضوعية: Pervious Concrete, Permeability, Porosity, Falling head permeability test, Constant head permeability test, Materials of engineering and construction. Mechanics of materials, TA401-492
الوصف: The use of Pervious Concrete (PC) increased in the last years as an alternative to solve the run-off problem. PC shows a high percentage of empty spaces/gaps, which vary from 10 to 35%, facilitating the flow of rain and water through its structure. PC presents higher k permeability coefficient compared to conventional concrete. Permeability is the main property of PC, although there is no standardized method that guarantees the correct and precise measurement of such property in laboratory conditions. Currently, two main methodologies are used to assess the permeability coefficient: the falling head and the constant head permeability tests. In that regard, the American Concrete Institute recommends the use of the first method, although no comparison was done between them. Furthermore, the recommendations do not consider the use of sustainable aggregates during the production of the PC. In this study, the permeability tests were explained and used to assess the permeability coefficient of different mixes of PC produced with sustainable aggregates. The experimental results were used to analyze the relationship between the porosity and the permeability of concrete and compare the performance of the falling head and constant head permeability tests. The study presents the advantages of performing the constant head permeability test to assess the permeability of the PC.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2214-5095
Relation: http://www.sciencedirect.com/science/article/pii/S2214509517301018; https://doaj.org/toc/2214-5095
DOI: 10.1016/j.cscm.2017.09.001
URL الوصول: https://doaj.org/article/402500ad73e54d70a3692ecd60c33fed
رقم الانضمام: edsdoj.402500ad73e54d70a3692ecd60c33fed
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:22145095
DOI:10.1016/j.cscm.2017.09.001