Academic Journal

Correction of estimation bias of predictive equations of energy expenditure based on wrist/waist-mounted accelerometers

التفاصيل البيبلوغرافية
العنوان: Correction of estimation bias of predictive equations of energy expenditure based on wrist/waist-mounted accelerometers
المؤلفون: Chin-Shan Ho, Chun-Hao Chang, Kuo-Chuan Lin, Chi-Chang Huang, Yi-Ju Hsu
المصدر: PeerJ, Vol 7, p e7973 (2019)
بيانات النشر: PeerJ Inc., 2019.
سنة النشر: 2019
المجموعة: LCC:Medicine
LCC:Biology (General)
مصطلحات موضوعية: Accelerometer, Energy expenditure, Wrist, Physical activity, Heart rate reserve, Medicine, Biology (General), QH301-705.5
الوصف: Background Using wearable inertial sensors to accurately estimate energy expenditure (EE) during an athletic training process is important. Due to the characteristics of inertial sensors, however, the positions in which they are worn can produce signals of different natures. To understand and solve this issue, this study used the heart rate reserve (HRR) as a compensation factor to modify the traditional empirical equation of the accelerometer EE sensor and examine the possibility of improving the estimation of energy expenditure for sensors worn in different positions. Methods Indirect calorimetry was used as the criterion measure (CM) to measure the EE of 90 healthy adults on a treadmill (five speeds: 4.8, 6.4, 8.0, 9.7, and 11.3 km/h). The measurement was simultaneously performed with the ActiGraph GT9X-Link (placed on the wrist and waist) with the Polar H10 Heart Rate Monitor. Results At the same exercise intensity, the EE measurements of the GT9X on the wrist and waist had significant differences from those of the CM (p < 0.05). By using multiple regression analysis—utilizing values from vector magnitudes (VM), body weight (BW) and HRR parameters—accuracy of EE estimation was greatly improved compared to traditional equation. Modified models explained a greater proportion of variance (R2) (wrist: 0.802; waist: 0.805) and demonstrated a good ICC (wrist: 0.863, waist: 0.889) compared to Freedson’s VM3 Combination equation (R2: wrist: 0.384, waist: 0.783; ICC: wrist: 0.073, waist: 0.868). Conclusions The EE estimation equation combining the VM of accelerometer measurements, BW and HRR greatly enhanced the accuracy of EE estimation based on data from accelerometers worn in different positions, particularly from those on the wrist.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2167-8359
50181483
Relation: https://peerj.com/articles/7973.pdf; https://peerj.com/articles/7973/; https://doaj.org/toc/2167-8359
DOI: 10.7717/peerj.7973
URL الوصول: https://doaj.org/article/3fe1d4a50181483b8ca97762789ad9c4
رقم الانضمام: edsdoj.3fe1d4a50181483b8ca97762789ad9c4
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:21678359
50181483
DOI:10.7717/peerj.7973