Comparative analysis of novel esophageal pressure monitoring catheters versus commercially available alternatives in a biomechanical model of the thoracic cavity

التفاصيل البيبلوغرافية
العنوان: Comparative analysis of novel esophageal pressure monitoring catheters versus commercially available alternatives in a biomechanical model of the thoracic cavity
المؤلفون: Gabriella Abbate, Sebastiano Maria Colombo, Clayton Semenzin, Noriko Sato, Keibun Liu, Carmen Ainola, Angelo Milani, Gabriele Fior, Nchafatso Obonyo, Nicole White, Davide Chiumello, Jo Pauls, Jacky Y. Suen, John F. Fraser, Gianluigi Li Bassi
المصدر: Scientific Reports, Vol 14, Iss 1, Pp 1-12 (2024)
بيانات النشر: Nature Portfolio, 2024.
سنة النشر: 2024
المجموعة: LCC:Medicine
LCC:Science
مصطلحات موضوعية: Esophageal pressure, Nasogastric catheter, Trans-esophageal pressure, Mechanical ventilation, Intensive care unit, Medicine, Science
الوصف: Abstract Transpulmonary pressure can be estimated using esophageal balloon (EB) catheters, which come in a variety of manufacturing configurations. We assessed the performance of novel polyurethane EB designs, Aspisafe NG and NG+, against existing alternatives. We created a biomechanical model of the chest cavity using a plastic chamber and an ex-vivo porcine esophagus. The chamber was pressurized (− 20 and + 20 cmH2O) to simulate pleural pressures. We conducted tests with various EB inflation volumes and measured transesophageal pressure (TEP). TEP measurement was defined as accurate when the difference between pressure within the EB and chamber was 0 ± 1 cmH2O. We computed the minimal (Vaccuracy-min) and maximal (Vaccuracy-max) EB inflation volumes of accuracy. Inflation volumes were further validated using a surrogate method derived by the clinically validated positive pressure occlusion test (PPOT). When the esophageal balloons were filled with inflation volumes within the range provided by the manufacturers, the accuracy of TEP measurements was marginal. Our tests found median Vaccuracy-min across EB of 0.00–0.50 mL (p = 0.130), whereas Vaccuracy-max ranged 0.50–2.25 mL (p = 0.002). Post PPOT validation, median TEP was − 0.4 cmH2O (− 1.5 to 0.3) (p
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2045-2322
Relation: https://doaj.org/toc/2045-2322
DOI: 10.1038/s41598-024-59790-1
URL الوصول: https://doaj.org/article/3ae268be38574193ab8b2aa05ca0aa9e
رقم الانضمام: edsdoj.3ae268be38574193ab8b2aa05ca0aa9e
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20452322
DOI:10.1038/s41598-024-59790-1