Academic Journal

Titanium nitride coating of pectus bar increases metal contamination after minimally-invasive repair of pectus excavatum.

التفاصيل البيبلوغرافية
العنوان: Titanium nitride coating of pectus bar increases metal contamination after minimally-invasive repair of pectus excavatum.
المؤلفون: Caroline Fortmann, Thomas Göen, Soeren Wiesner, Jan Hegermann, Rim Kiblawi, Martha Dohna, Benno M Ure, Diane Miriam Renz, Claus Petersen, Joachim F Kuebler
المصدر: PLoS ONE, Vol 18, Iss 10, p e0292616 (2023)
بيانات النشر: Public Library of Science (PLoS), 2023.
سنة النشر: 2023
المجموعة: LCC:Medicine
LCC:Science
مصطلحات موضوعية: Medicine, Science
الوصف: IntroductionPrevious studies demonstrated a release of toxic metals, e.g. nickel and chromium, from stainless steel bars used for minimally invasive repair of pectus excavatum (MIRPE). In the present study, we investigated the impact of titanium nitride coating on the metal release and exposure of MIRPE patients.Material and methodsWe analyzed the courses of nickel and chromium levels in blood, urine and local tissue in patients undergoing MIRPE with a titanium nitride coated pectus bar between 03/2017 and 10/2018. Sample collection was scheduled prior to MIRPE, at defined postoperative time points and at bar removal. Additionally, we evaluated irritative symptoms. Results were compared to a control group who received uncoated stainless steel bars in a previous time period (03/2015-02/2017).Results12 patients received coated pectus bars (mean age 15.7 years). The control group included 28 patients. After implantation of a titanium nitride coated bar, significant increase in systemic nickel and chromium levels after one, two and three years was noted. In an interim analysis one year after MIRPE, we observed patients with coated bars to have significantly elevated trace metal values compared to the control group. This elevation persisted throughout the observation period. Tissue metal values were also significantly increased. Irritative symptoms occurred significantly more often in study patients compared to controls (50.0% vs. 14.3%).ConclusionsCoating of pectus bars with titanium nitride failed to reduce metal contamination after MIRPE. Instead, it resulted in a significant increase of trace metal levels after MIRPE, compared to patients with stainless steel bars, which may be explained by wear of the coating and inter-component mobilization processes.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1932-6203
Relation: https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0292616&type=printable; https://doaj.org/toc/1932-6203
DOI: 10.1371/journal.pone.0292616&type=printable
DOI: 10.1371/journal.pone.0292616
URL الوصول: https://doaj.org/article/304937596000439eb17bbef13e0e44ed
رقم الانضمام: edsdoj.304937596000439eb17bbef13e0e44ed
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:19326203
DOI:10.1371/journal.pone.0292616&type=printable