Academic Journal

A Customized 3D-Printed Bolus for High-Risk Breast Cancer with Skin Infiltration: A Pilot Study

التفاصيل البيبلوغرافية
العنوان: A Customized 3D-Printed Bolus for High-Risk Breast Cancer with Skin Infiltration: A Pilot Study
المؤلفون: Silvia Takanen, Anna Ianiro, Paola Pinnarò, Erminia Infusino, Laura Marucci, Antonella Soriani, Giuseppe Sanguineti, Giuseppe Iaccarino
المصدر: Current Oncology, Vol 31, Iss 9, Pp 5224-5232 (2024)
بيانات النشر: MDPI AG, 2024.
سنة النشر: 2024
المجموعة: LCC:Neoplasms. Tumors. Oncology. Including cancer and carcinogens
مصطلحات موضوعية: breast cancer, skin toxicity, dosimetric analysis, 3D-printed bolus, Neoplasms. Tumors. Oncology. Including cancer and carcinogens, RC254-282
الوصف: Background: In high-risk breast cancer patients with skin infiltration, the administration of a uniform dose to superficial tissues is fundamental in order to reduce local skin relapse. A personalized bolus may prevent the potential inadequate dose distribution of a standard bolus due to air gaps between the bolus and the skin. In this pilot study, we introduced into clinical practice the use of a personalized 3D-printed bolus filled with ultrasound transmission gel. Methods: Seven patients undergoing radiotherapy after mastectomy were selected. A 3D-printed bolus dosimetric assessment was performed with MOSFET dosimeters on an anthropomorphic phantom and, subsequently, on three selected cases with increasing bolus shape irregularity. Acute/late toxicity and local control were assessed. Results: Overall, for the clinical cases, the percentage median difference between the measured and calculated doses was −2.7% (−7.0–4.9%). The median follow-up was 21 months. After two years, one patient showed G2 pain, one patient manifested G1 telangiectasia, one patient showed G1 hyperpigmentation, and two patients had no relevant toxicity. Conclusions: A personalized 3D-printed bolus filled with ultrasound gel may easily reproduce the standard bolus’ consistency and provide accurate coverage of the target area with tolerable acute/late toxicity grades. This is a pilot study, and further investigations are needed.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1718-7729
1198-0052
Relation: https://www.mdpi.com/1718-7729/31/9/386; https://doaj.org/toc/1198-0052; https://doaj.org/toc/1718-7729
DOI: 10.3390/curroncol31090386
URL الوصول: https://doaj.org/article/d2e1844869cc4a1c80a176915691432a
رقم الانضمام: edsdoj.2e1844869cc4a1c80a176915691432a
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:17187729
11980052
DOI:10.3390/curroncol31090386