Optimization of Shear Resistance in Horizontal Joints of Prefabricated Shear Walls through Post-Cast Epoxy Resin Concrete Applications

التفاصيل البيبلوغرافية
العنوان: Optimization of Shear Resistance in Horizontal Joints of Prefabricated Shear Walls through Post-Cast Epoxy Resin Concrete Applications
المؤلفون: Peiqi Chen, Shilong Zhao, Pengzhan Xu, Xiaojie Zhou, Yueqiang Li
المصدر: Buildings, Vol 14, Iss 10, p 3119 (2024)
بيانات النشر: MDPI AG, 2024.
سنة النشر: 2024
المجموعة: LCC:Building construction
مصطلحات موضوعية: epoxy resin concrete, prefabricated shear wall, horizontal joint, shear resistance, experiment, finite element analysis, Building construction, TH1-9745
الوصف: The horizontal joint is a critical component of the prefabricated shear wall structure, responsible for supporting both horizontal shear forces and vertical loads along with the wall, thereby influencing the overall structural performance. This study employs direct shear testing and finite element analysis to investigate the horizontal joint in walls with ring reinforcement. It examines the impact of various factors on joint shear performance, including the type of joint material, joint configuration, buckling length of ring reinforcement, strength of precast concrete, reinforcement ratio of ring reinforcement and dowel bars, and the effect of horizontal binding force. The findings indicate that the shear bearing capacity and stiffness of joints incorporating post-cast epoxy resin concrete and keyways are comparable or superior to those of integrally cast specimens. A larger buckling length in ring reinforcement may reduce shear strength, suggesting an optimal buckling length at approximately one-third of the joint width. As the strength of precast concrete increases, ductility decreases while bearing capacity increases, initially at an increasing rate that subsequently declines. Optimal results are achieved when the strength of precast concrete closely matches that of the post-cast epoxy concrete. Enhancing the reinforcement ratio of ring reinforcement improves shear capacity, but excessively high ratios significantly reduce ductility. It is recommended that the diameter of ring reinforcement be maintained between 10 mm and 12 mm, with a reinforcement ratio between 0.79% and 1.13%. Increasing horizontal restraint enhances stiffness and shear capacity but reduces ductility; thus, the axial compression ratio should not exceed 0.5.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2075-5309
Relation: https://www.mdpi.com/2075-5309/14/10/3119; https://doaj.org/toc/2075-5309
DOI: 10.3390/buildings14103119
URL الوصول: https://doaj.org/article/2afc9a37bee94dc1ad0f5e414c8b68d1
رقم الانضمام: edsdoj.2afc9a37bee94dc1ad0f5e414c8b68d1
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20755309
DOI:10.3390/buildings14103119