Academic Journal

Validation of a handheld refractometer to assess Merino ewe colostrum and transition milk quality

التفاصيل البيبلوغرافية
العنوان: Validation of a handheld refractometer to assess Merino ewe colostrum and transition milk quality
المؤلفون: Bianca Agenbag, Alyce M. Swinbourne, Kiro Petrovski, William H. E.J. van Wettere
المصدر: Journal of Dairy Science, Vol 106, Iss 2, Pp 1394-1402 (2023)
بيانات النشر: Elsevier, 2023.
سنة النشر: 2023
المجموعة: LCC:Dairy processing. Dairy products
مصطلحات موضوعية: sheep, IgG concentration, refractometer, colostrum quality, lactation, Dairy processing. Dairy products, SF250.5-275, Dairying, SF221-250
الوصف: ABSTRACT: Colostrum quality is generally defined by the IgG concentration in colostrum, and many methods have been used to assess it. Methods to measure colostrum quality both in the laboratory and in the field have been validated in cattle; however, this is only a recent topic of interest for sheep colostrum. Laboratory-based methods are often time consuming and require trained personnel compared with new handheld evaluation tools such as the digital Brix refractometer, which gives real-time results. The aims of this study were to (1) evaluate the relationship between the digital Brix refractometer and constituents indicative of quality (IgG, protein, fat, and lactose) in colostrum and transition milk, and (2) determine an appropriate Brix % cut-off value for the Brix refractometer in sheep colostrum and transition milk. The study used 50 colostrum samples (collected at 0 h postpartum, before lambs' sucking) and 169 transitional milk samples (collected at 4 and 24 h postpartum, after lambs had sucked) collected over 6 lambing trials in 2 years (2019 and 2020). We concluded that the Brix refractometer results correlated weakly with IgG concentration determined by radial immunodiffusion assay in colostrum collected at 0 h postpartum (r = 0.11) and in transition milk collected at 4 h postpartum (r = 0.12); however, a moderate to strong correlation was shown in transition milk samples collected at 24 h (r = 0.66). Brix % was significantly correlated with fat %, lactose %, and protein % at all timepoints. To determine an appropriate Brix % cut-off value indicating an IgG concentration of 20 mg/mL, we analyzed sensitivity and specificity of the Brix refractometer at 0, 4, and 24 h. In samples collected at 0 and 4 h, the highest combination of sensitivity, specificity, and accuracy was achieved at a Brix % cut-off value of 29%; in samples collected at 24 h postpartum, a Brix % cut-off value of 27% gave the highest sensitivity, specificity, and accuracy. Overall, the Brix refractometer has potential as a useful in-field tool for researchers and producers in both extensively and intensively managed flocks to measure and determine the quality of sheep colostrum and transition milk.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 0022-0302
Relation: http://www.sciencedirect.com/science/article/pii/S0022030222006919; https://doaj.org/toc/0022-0302
DOI: 10.3168/jds.2022-22022
URL الوصول: https://doaj.org/article/2978c15e7cb64d818370af4b49f2f553
رقم الانضمام: edsdoj.2978c15e7cb64d818370af4b49f2f553
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:00220302
DOI:10.3168/jds.2022-22022