Albuminuria and neck circumference are determinate factors of successful accurate estimation of glomerular filtration rate in high cardiovascular risk patients.

التفاصيل البيبلوغرافية
العنوان: Albuminuria and neck circumference are determinate factors of successful accurate estimation of glomerular filtration rate in high cardiovascular risk patients.
المؤلفون: Po-Jen Hsiao, Hung-Che Lin, Shih-Tai Chang, Jen-Te Hsu, Wei-Shiang Lin, Chang-Min Chung, Jung-Jung Chang, Kuo-Chun Hung, Yun-Wen Shih, Fu-Chi Chen, Fu-Kang Hu, Yi-Syuan Wu, Chi-Wen Chang, Sui-Lung Su, Chi-Ming Chu
المصدر: PLoS ONE, Vol 13, Iss 2, p e0185693 (2018)
بيانات النشر: Public Library of Science (PLoS), 2018.
سنة النشر: 2018
المجموعة: LCC:Medicine
LCC:Science
مصطلحات موضوعية: Medicine, Science
الوصف: Estimated glomerular filtration rate (eGFR) is used for diagnosis of chronic kidney disease (CKD). The eGFR models based on serum creatinine or cystatin C are used more in clinical practice. Albuminuria and neck circumference are associated with CKD and may have correlations with eGFR.We explored the correlations and modelling formulates among various indicators such as serum creatinine, cystatin C, albuminuria, and neck circumference for eGFR.Cross-sectional study.We reviewed the records of patients with high cardiovascular risk from 2010 to 2011 in Taiwan. 24-hour urine creatinine clearance was used as the standard. We utilized a decision tree to select for variables and adopted a stepwise regression method to generate five models. Model 1 was based on only serum creatinine and was adjusted for age and gender. Model 2 added serum cystatin C, models 3 and 4 added albuminuria and neck circumference, respectively. Model 5 simultaneously added both albuminuria and neck circumference.Total 177 patients were recruited in this study. In model 1, the bias was 2.01 and its precision was 14.04. In model 2, the bias was reduced to 1.86 with a precision of 13.48. The bias of model 3 was 1.49 with a precision of 12.89, and the bias for model 4 was 1.74 with a precision of 12.97. In model 5, the bias could be lower to 1.40 with a precision of 12.53.In this study, the predicting ability of eGFR was improved after the addition of serum cystatin C compared to serum creatinine alone. The bias was more significantly reduced by the calculation of albuminuria. Furthermore, the model generated by combined albuminuria and neck circumference could provide the best eGFR predictions among these five eGFR models. Neck circumference can be investigated potentially in the further studies.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1932-6203
Relation: http://europepmc.org/articles/PMC5796684?pdf=render; https://doaj.org/toc/1932-6203
DOI: 10.1371/journal.pone.0185693
URL الوصول: https://doaj.org/article/21889a3687b34771957d33a1ce41f829
رقم الانضمام: edsdoj.21889a3687b34771957d33a1ce41f829
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:19326203
DOI:10.1371/journal.pone.0185693