التفاصيل البيبلوغرافية
العنوان: |
A Common Capacitor Based Three Level STATCOM and Design of DFIG Converter for a Zero-Voltage Fault Ride-Through Capability |
المؤلفون: |
Naeem M. S. Hannoon, D. V. N. Ananth, Muhamad Nabil Bin Hidayat, P. S. R. Chowdary, V. V. S. S. S. Chakravarthy, Kona Sivashankar, Suresh Chandra Satapathy |
المصدر: |
IEEE Access, Vol 9, Pp 105153-105179 (2021) |
بيانات النشر: |
IEEE, 2021. |
سنة النشر: |
2021 |
المجموعة: |
LCC:Electrical engineering. Electronics. Nuclear engineering |
مصطلحات موضوعية: |
Doubly-fed induction generator (DFIG), field oriented control (FOC), common-capacitor based STATCOM, voltage compensation, balanced and unbalanced faults, zero-voltage fault ride through, Electrical engineering. Electronics. Nuclear engineering, TK1-9971 |
الوصف: |
To meet the augmented load power demand, the doubly-fed induction generator (DFIG) based wind electrical power conversion system (WECS) is a better alternative. Further, to enhance the power flow capability and raise security margin in the power system, the STATCOM type FACTS devices can be adopted as an external reactive power source. In this paper, a three-level STATCOM coordinates the system with its dc terminal voltage is connected to the common back-to-back converters. Hence, a lookup table-based control scheme in the outer control loops is adopted in the Rotor Side Converter (RSC) and the grid side converter (GSC) of DFIG to improve power flow transfer and better dynamic as well as transient stability. Moreover, the DC capacitor bank of the STATCOM and DFIG converters connected to a common dc point. The main objectives of the work are to improve voltage mitigation, operation of DFIG during symmetrical and asymmetrical faults, and limit surge currents. The DFIG parameters like winding currents, torque, rotor speed are examined at 50%, 80% and 100% comparing with earlier works. Further, we studied the DFIG system performance at 30%, 60%, and 80% symmetrical voltage dip. Zero-voltage fault ride through is investigated with proposed technique under symmetrical and asymmetrical LG fault for super-synchronous (1.2 p.u.) speed and sub-synchronous (0.8 p.u.) rotor speed. Finally, the DFIG system performance is studied with different phases to ground faults with and without a three-level STATCOM. |
نوع الوثيقة: |
article |
وصف الملف: |
electronic resource |
اللغة: |
English |
تدمد: |
2169-3536 |
Relation: |
https://ieeexplore.ieee.org/document/9490219/; https://doaj.org/toc/2169-3536 |
DOI: |
10.1109/ACCESS.2021.3098187 |
URL الوصول: |
https://doaj.org/article/15ca38008bd3420babcd26f7f079aafa |
رقم الانضمام: |
edsdoj.15ca38008bd3420babcd26f7f079aafa |
قاعدة البيانات: |
Directory of Open Access Journals |