Academic Journal

Higher scanning frequency is correlated with less fear of hypoglycemia in type 1 diabetes patients using isCGM

التفاصيل البيبلوغرافية
العنوان: Higher scanning frequency is correlated with less fear of hypoglycemia in type 1 diabetes patients using isCGM
المؤلفون: Jerzy Hohendorff, Przemyslaw Witek, Michal Kania, Maria Sudol, Katarzyna Hajduk, Adam Stepien, Katarzyna Cyganek, Beata Kiec-Wilk, Tomasz Klupa, Maciej T. Malecki
المصدر: Frontiers in Endocrinology, Vol 13 (2022)
بيانات النشر: Frontiers Media S.A., 2022.
سنة النشر: 2022
المجموعة: LCC:Diseases of the endocrine glands. Clinical endocrinology
مصطلحات موضوعية: continous glucose monitoring, intermittently scanned CGM, ambulatory glucose profile (AGP), fear of hypoglycemia, type 1 diabetes, time in range, Diseases of the endocrine glands. Clinical endocrinology, RC648-665
الوصف: BackgroundFrequent scanning of intermittently scanned continuous glucose monitoring (isCGM) devices is associated with improvements in glycemic indices. Limited data is available for its correlation with fear of hypoglycemia (FOH), an established factor affecting quality of life and glycemic control in type 1 diabetes (T1DM).AimThe aim of the study was to analyze the association of sensor scanning frequency with FOH and glycemic indices in T1DM patients using isCGM.Subjects and methodsT1DM patients using isCGM were eligible. Clinical data and Ambulatory Glucose Profile (AGP) reports were obtained from medical records. At outpatient visits, AGP of last 14 days prior to visit were analyzed and FOH was assessed using Hypoglycemia Fear Survey II (HFS II).ResultsWe included 77 consecutive T1DM patients (58 females, 19 males). Mean age was 34.1 ± 10.2 years and mean T1DM duration was 14.7 ± 12.0 years. Baseline mean glycemic indices were as follows: mean glucose - 155.8 ± 29.8 mg/dL; GMI - 53.3 ± 7.5 mmol/mol; TIR - 66.4 ± 17.8%; TBR70 - 4.5 ± 4.1%; TBR54 - 0.6 ± 1.2%; TAR180 - 29.2 ± 17.9%; TAR250 - 9.6 ± 10.4%; %CV - 36.7 ± 8.3. Average scanning frequency was 13.8 ± 7.8 scans/day. Mean HFS II scores were 16.1 ± 7.2 and 18.7 ± 12.2 in behavior and worry subscale, respectively. Correlation was confirmed between scanning frequency and mean glucose, GMI, TIR, TBR70, TAR180, TAR250, %CV and HFS II total, and HFS II - B (p
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1664-2392
Relation: https://www.frontiersin.org/articles/10.3389/fendo.2022.996933/full; https://doaj.org/toc/1664-2392
DOI: 10.3389/fendo.2022.996933
URL الوصول: https://doaj.org/article/1479098455c74b54b5a68af3e4325be4
رقم الانضمام: edsdoj.1479098455c74b54b5a68af3e4325be4
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:16642392
DOI:10.3389/fendo.2022.996933