Academic Journal
العنوان: | [Untitled] |
---|---|
المؤلفون: | Rajiv Bharadwaj, Juan G. Santiago, Bijan Mohammadi |
المساهمون: | The Pennsylvania State University CiteSeerX Archives |
المصدر: | http://microfluidics.stanford.edu/Publications/ElectrokineticFlows/Bharadwaj Opt of CE Injections Electrophoresis.pdf. |
المجموعة: | CiteSeerX |
مصطلحات موضوعية: | Electrokinetic injection / Microchip / One-chip capillary electrophoresis EL 5080 |
الوصف: | Design and optimization of on-chip capillary electrophoresis We present a systematic, experimentally validated method of designing electrokinetic injections for on-chip capillary electrophoresis applications. This method can be used to predict point-wise and charge-coupled device (CCD)-imaged electropherograms using estimates of species mobilities, diffusivities and initial sample plug parameters. A simple Taylor dispersion model is used to characterize electrophoretic separations in terms of resolution and signal-to-noise ratio (SNR). Detection convolutions using Gaussian and Boxcar detector response functions are used to relate optimal condi-tions for resolution and signal as a function of relevant system parameters including electroosmotic mobility, sample injection length, detector length scale, and the length-to-detector. Analytical solutions show a tradeoff between signal-to-noise ratio and resolution with respect to dimensionless injection width and length to the detector. In contrast, there is no tradeoff with respect to the Peclet number as increases in Peclet number favor both SNR and separation solution (R). We validate our model with quan-titative epifluorescence visualizations of electrophoretic separation experiments in a simple cross channel microchip. For the pure advection regime of dispersion, we use numerical simulations of the transient convective diffusion processes associated with electrokinetics together with an optimization algorithm to design a voltage control scheme which produces an injection plug that has minimal advective dispersion. We also validate this optimal injection scheme using fluorescence visualizations. These validations show that optimized voltage scheme produces injections with a standard deviation less than one-fifth of the width of the microchannel. |
نوع الوثيقة: | text |
وصف الملف: | application/pdf |
اللغة: | English |
Relation: | http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.492.5120; http://microfluidics.stanford.edu/Publications/ElectrokineticFlows/Bharadwaj Opt of CE Injections Electrophoresis.pdf |
الاتاحة: | http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.492.5120 http://microfluidics.stanford.edu/Publications/ElectrokineticFlows/Bharadwaj Opt of CE Injections Electrophoresis.pdf |
Rights: | Metadata may be used without restrictions as long as the oai identifier remains attached to it. |
رقم الانضمام: | edsbas.F774FA43 |
قاعدة البيانات: | BASE |
الوصف غير متاح. |