Academic Journal
Clinical outcome of dental implants after maxillary sinus augmentation with and without bone grafting: a retrospective evaluation
العنوان: | Clinical outcome of dental implants after maxillary sinus augmentation with and without bone grafting: a retrospective evaluation |
---|---|
المؤلفون: | Tartaglia G. M., Poli P. P., Connelly S. T., Maiorana C., Farronato D., Taschieri S. |
المساهمون: | Tartaglia, G. M., Poli, P. P., Connelly, S. T., Maiorana, C., Farronato, D., Taschieri, S. |
سنة النشر: | 2021 |
المجموعة: | IRInSubria - Institutional Repository Insubria (Università degli Studi dell’Insubria) |
مصطلحات موضوعية: | Bone substitute, Dental implant, Edentulism, Grafting material, Sinus augmentation, Survival analysis |
الوصف: | (1) Background: The purpose of the present study was to retrospectively evaluate and compare the outcome of two sinus augmentation grafting protocols using a xenograft or blood clot alone over a 72-month follow-up. (2) Methods: Patients who received simultaneous lateral sinus floor augmentation and implant placement were included. Subjects were divided into two groups according to the grafting material, namely xenograft or blood clot, and into sub-groups based on the residual alveolar bone height (RABH) below the maxillary sinus, namely 4 to 6 mm or >6 mm. Kaplan–Meier survival estimates were calculated for each material group and for each sub-group at 1, 3, and 6 years. (3) Results: In total, 289 implants inserted in 136 patients with a one-stage procedure were considered. A total of 35 failures were registered. Overall survival rates were 94.2% for xenograft and 85.9% for blood clot alone at 1 year, 91.1% and 81.6% at 3 years, and 91.1% and 78.7% at 6 years. (4) Conclusions: In patients with 4–6 mm RABH, graftless interventions exploiting blood clot alone were not as successful as those using xenograft. When the RABH is low, sinus floor augmentation associated with grafting materials should be preferred whenever possible. |
نوع الوثيقة: | article in journal/newspaper |
وصف الملف: | ELETTRONICO |
اللغة: | English |
Relation: | info:eu-repo/semantics/altIdentifier/pmid/34064784; info:eu-repo/semantics/altIdentifier/wos/WOS:000662600000001; volume:14; issue:10; firstpage:1; lastpage:15; numberofpages:15; journal:MATERIALS; http://hdl.handle.net/11383/2136070; info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85106530805 |
DOI: | 10.3390/ma14102479 |
الاتاحة: | http://hdl.handle.net/11383/2136070 https://doi.org/10.3390/ma14102479 |
Rights: | info:eu-repo/semantics/openAccess |
رقم الانضمام: | edsbas.EB7DE6A6 |
قاعدة البيانات: | BASE |
DOI: | 10.3390/ma14102479 |
---|