Academic Journal

A comprehensive HPLC–MS-MS screening method for 77 new psychoactive substances, 24 classic drugs and 18 related metabolites in blood, urine and oral fluid

التفاصيل البيبلوغرافية
العنوان: A comprehensive HPLC–MS-MS screening method for 77 new psychoactive substances, 24 classic drugs and 18 related metabolites in blood, urine and oral fluid
المؤلفون: Di Trana A., Mannocchi G., Pirani F., La Maida N., Gottardi M., Pichini S., Busardo F. P.
المساهمون: Di Trana, A., Mannocchi, G., Pirani, F., La Maida, N., Gottardi, M., Pichini, S., Busardo, F. P.
سنة النشر: 2020
المجموعة: Università Politecnica delle Marche: IRIS
مصطلحات موضوعية: Body Fluid, Calibration, Central Nervous System Agent, Chromatography, High Pressure Liquid, Liquid, Human, Illicit Drug, Limit of Detection, Psychotropic Drug, Reproducibility of Result, Saliva, Substance Abuse Detection, Tandem Mass Spectrometry
الوصف: To date, more than 800 molecules are classified as New Psychoactive Substances (NPS), and it is reported that this number increases every year. Whereas several cases of polydrug consumption that led to acute intoxication and death are reported, a lack of effective analytical screening method to detect NPS and classical drug of abuse in human matrices affects the prompt identification of the probable cause of intoxication in emergency department of hospitals. In this concern, a fast, simple and comprehensive high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS-MS) screening method to detect and quantify 77 NPS, 24 classic drugs and 18 related metabolites has been successfully developed and validated in blood, urine and oral fluid. A small volume (100 μL) of whole blood samples spiked with internal standard deuterated mixture was added to 70 μL of M3® buffer, and after precipitation of blood proteins, the supernatant was evaporated to dryness and reconstituted in 1 mL of mobile phase. Same volume (100 μL) of urine and oral fluid samples spiked with internal standard deuterated mix were only diluted with 500 μL of M3® reagent. One microliter of samples of each matrix was injected into HPLC–MS-MS equipment. The run time lasted 10 min with a gradient mobile phase. Mass spectrometric analysis was performed in positive ion multiple reaction monitoring mode. The method was linear for all analytes under investigation with a determination coefficient always better than 0.99. The calibration range for blood and oral fluid was from limits of quantification (LOQs) to 200 ng/mL, whereas that for urine was LOQs to 1000 ng/mL. Recovery and matrix effect were always higher than 80%, whereas intra-assay and inter-assay precision were always better than 19% and accuracy was always within 19% of target in every matrix. Applicability of the method was verified by analysis of samples from real cases.
نوع الوثيقة: article in journal/newspaper
اللغة: English
Relation: info:eu-repo/semantics/altIdentifier/pmid/32816015; info:eu-repo/semantics/altIdentifier/wos/WOS:000606735000002; volume:44; issue:8; firstpage:769; lastpage:783; numberofpages:15; journal:JOURNAL OF ANALYTICAL TOXICOLOGY; https://hdl.handle.net/11566/286989; info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85098472014
DOI: 10.1093/jat/bkaa103
الاتاحة: https://hdl.handle.net/11566/286989
https://doi.org/10.1093/jat/bkaa103
Rights: info:eu-repo/semantics/openAccess
رقم الانضمام: edsbas.EAA4B4E0
قاعدة البيانات: BASE