مصطلحات موضوعية: | SEPIC Converter, Over Charging, Life Time, Constant Voltage, Constant Current, Set Point |
الوصف: | Rechargeable batteries are the most widely used medium for storing energy today. One type of rechargeable battery that is widely used is lithium-ion batteries. The large use of lithium-ion batteries in society requires companies to conduct research so that the life time of these batteries can last a long time and charging can take place quickly. Charging system at this time is less efficient in charging lithium batteries where the time needed is still quite long where when lithium batteries are charged with a long time can cause the battery to heat up quickly and can reduce the life time of the battery. To overcome this, a system is needed that can control the battery charger process so that the output voltage and current are constant and battery charging is faster. It is hoped that the SEPIC converter system can help many people who forget to unplug the power supply during the charging process so as to maintain the life time of the battery. Setting the output voltage and current in the DC-DC converter can be done using an Adaptive Neuro Fuzzy Inference System which aims to keep the output of SEPIC stable according to the setting point. In this system, the DC-DC converter used is a SEPIC converter which can increase and decrease the output voltage for battery charging. The battery charging process uses the CC-CV method. In the test, the average error is 0.025% where when the SOC is 60% to 80% the average error is 0.04% and when the SOC is 80% to 95% the average error is 0.0005%. |
نوع الوثيقة: | article in journal/newspaper |
وصف الملف: | application/pdf |
اللغة: | English |
Relation: | https://kinetik.umm.ac.id/index.php/kinetik/article/view/1954/124124391; https://kinetik.umm.ac.id/index.php/kinetik/article/view/1954 |
DOI: | 10.22219/kinetik.v9i2.1954 |
الاتاحة: | https://kinetik.umm.ac.id/index.php/kinetik/article/view/1954 https://doi.org/10.22219/kinetik.v9i2.1954 |
Rights: | Copyright (c) 2024 Suryono, Indhana Sudiharto, Dimas Okky Anggriawan, Mohammad Jufriyadi ; https://creativecommons.org/licenses/by-nc-sa/4.0 |
رقم الانضمام: | edsbas.E91480EB |
قاعدة البيانات: | BASE |
DOI: | 10.22219/kinetik.v9i2.1954 |
---|