Parametric Study on Design Factors of the Shutdown Cooling Heat Exchanger Using the Taguchi Method |
المؤلفون: |
Kim, Seong Hoon, Ryu, Seung Yeob, Choi, Byung Seon, Yoon, Juhyeon, Bae, Yoon Yeong, Zee, Sung Kyun |
بيانات النشر: |
Korean Nuclear Society |
سنة النشر: |
2008 |
المجموعة: |
CLICK (Cooperative Link Center in KOREA) |
Time: |
5397, 62148 |
الوصف: |
The Taguchi method was applied to investigate the effect of design factors on the performance of the shutdown cooling heat exchanger in the SMART-P. This method provided the simulation matrix for the KDESCENT program and an efficient tool for analyzing the simulation results. Levels of the design factors were selected by the effectiveness-NTU method. From 18 runs with the KDESCENT program, it was found that the performance of the system was greatly influenced by the inlet temperature at the shell side and the mass flow rate of the reactor coolant at the tube side. After applying the Taguchi method, we identified the important design factor that should be controlled and designed carefully. This method provides an efficient way to estimate the influence of each design factor on a system performance. |