Academic Journal

An 8/15‐channel Tx/Rx head neck RF coil combination with region‐specific B 1 + shimming for whole‐brain MRI focused on the cerebellum at 7T

التفاصيل البيبلوغرافية
العنوان: An 8/15‐channel Tx/Rx head neck RF coil combination with region‐specific B 1 + shimming for whole‐brain MRI focused on the cerebellum at 7T
المؤلفون: Pfaffenrot, Viktor, Brunheim, Sascha, Rietsch, Stefan H. G., Koopmans, Peter J., Ernst, Thomas M., Kraff, Oliver, Orzada, Stephan, Quick, Harald H.
المصدر: Magnetic Resonance in Medicine ; volume 80, issue 3, page 1252-1265 ; ISSN 0740-3194 1522-2594
بيانات النشر: Wiley
سنة النشر: 2018
المجموعة: Wiley Online Library (Open Access Articles via Crossref)
الوصف: Purpose To design and evaluate an 8/15‐channel transmit/receive (Tx/Rx) head‐neck RF coil combination with region‐specific shimming for whole‐brain MRI with focus on improved functional MRI of the cerebellum at 7 T. Methods An 8‐channel transceiver RF head coil was combined with a 7‐channel receive‐only array. The noise parameters and acceleration capabilities of this 8Tx/15Rx coil setup were compared with a commercially available 1Tx/32Rx RF head coil. Region‐specific 8‐channel shimming was applied when using the 8Tx/15Rx RF coil. To evaluate the capability for functional MRI of the cerebellum, temporal SNR and statistical nonparametric maps for finger‐tapping experiments with 14 healthy subjects were derived by applying a variable slice thickness gradient‐echo echo‐planar functional MRI sequence. Results The 8Tx/15Rx setup had a lower maximum noise correlation between channels, but higher average correlations compared with the 1Tx/32Rx coil. Both RF coils exhibited identical g‐factors in the cerebellum with R = 3 acceleration. The enlarged FOV of the 8Tx/15Rx coil in combination with region‐specific shimming increased homogeneity of the transmission field and temporal SNR in caudal cerebellar regions. Temporal SNR losses in cranial parts were reduced, resulting in more highly significant voxels in the caudally activated areas and identical patterns in the cranial cerebellar parts during a finger‐tapping task. Conclusion Compared with the 1Tx/32Rx RF coil, the presented 8Tx/15Rx RF coil combination successfully improves functional MRI of the human cerebellum at 7 T while maintaining whole‐brain coverage. A clear temporal SNR gain in caudal cerebellar regions is shown.
نوع الوثيقة: article in journal/newspaper
اللغة: English
DOI: 10.1002/mrm.27125
الاتاحة: http://dx.doi.org/10.1002/mrm.27125
https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1002%2Fmrm.27125
https://onlinelibrary.wiley.com/doi/pdf/10.1002/mrm.27125
Rights: http://onlinelibrary.wiley.com/termsAndConditions#vor
رقم الانضمام: edsbas.DFAE20F3
قاعدة البيانات: BASE