Academic Journal

A Study on Durability Parameters of Ferrocement

التفاصيل البيبلوغرافية
العنوان: A Study on Durability Parameters of Ferrocement
المؤلفون: Nivate Siddhesh, Makwana Mahesh, Kulkarni Mrudula
المصدر: E3S Web of Conferences, Vol 405, p 04034 (2023)
بيانات النشر: EDP Sciences
سنة النشر: 2023
المجموعة: Directory of Open Access Journals: DOAJ Articles
مصطلحات موضوعية: ferrocement, durability, reinforcement, mesh, corrosion, compressive strength, sulphate attack test, sorpivity test, water penetration test, Environmental sciences, GE1-350
الوصف: Ferrocement is formed of a thin layer of cement mortar that has been strengthened with multiple layers of wire mesh with a diameter of between 0.5 mm to 1 mm. To evaluate the durability criteria for the specimen, a series of cubes and cylinders were cast in this experiment using a mortar mix at a ratio of 1:3 and a water-cement ratio of 0.40 was selected. In this study, the ability of the ferrocement to endure water penetration, sorptivity, and resistance to sulphates were examined. The curing period was chosen to be 28, 56, and 90 days, respectively, in order to track changes in the outcome and investigate the effects of the various curing times on the ferrocement. In order to measure the rate of water absorption by capillarity rise, Sorptivity test was conducted in accordance with ASTM C1585-04. The average absorption rate at day 9 was found to be 84.87 x 10-7 mm/s1/2, 93.78 x10-7mm/s1/2, and 96.34x10-7 mm/s1/2 for 28, 56, and 90 days of curing respectively. The Sulphate attack test was conducted as per ASTM C 1012-2010. The mass loss was observed to be 0.28%, 0.32%, and 0.33% of the original mass, while the strength loss was 6.96%, 6.44%, and 6.33% for the curing periods of 28, 56, and 90 days respectively. According to DIN-1048, part 5, Water permeability test was conducted. Water was pressured with 500 KPa on the specimen to determine its water penetration. The average water penetration of the specimen was found to be 22.33 mm, 18.67 mm, and 14.33 mm for the corresponding curing periods of 28, 56, and 90 days. The results were within the range twaswere specified in the respective code, and they were judged acceptable in terms of the ferrocement's durability guidelines.
نوع الوثيقة: article in journal/newspaper
اللغة: English
French
تدمد: 2267-1242
Relation: https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/42/e3sconf_icstce2023_04034.pdf; https://doaj.org/toc/2267-1242; https://doaj.org/article/b2db039753d64342af51b42a62599a28
DOI: 10.1051/e3sconf/202340504034
الاتاحة: https://doi.org/10.1051/e3sconf/202340504034
https://doaj.org/article/b2db039753d64342af51b42a62599a28
رقم الانضمام: edsbas.DC775714
قاعدة البيانات: BASE
الوصف
تدمد:22671242
DOI:10.1051/e3sconf/202340504034