Performance evaluation of hybrid earth pipe cooling with horizontal piping system

التفاصيل البيبلوغرافية
العنوان: Performance evaluation of hybrid earth pipe cooling with horizontal piping system
المؤلفون: Ahmed, Shams Forruque., Khan, Mohammad Masud Kamal., Maung Than Oo, Amanullah., Rasul, Mohammad., Hassan, N. M. S.
المصدر: Ahmed, SF, Khan, MMK, Maung Than Oo, A, Rasul, M & Hassan, NMS 2016, 'Performance evaluation of hybrid earth pipe cooling with horizontal piping system', in MMK Khan & NMS Hassan (eds.), Thermofluid Modeling for Energy Efficiency Applications, Elsevier, London, UK., http://dx.doi.org/10.1016/B978-0-12-802397-6.00001-4
بيانات النشر: Elsevier
سنة النشر: 2016
المجموعة: Central Queensland University: aCQUIRe
مصطلحات موضوعية: Applied research, 850502 Geothermal Energy, 850704 Residential Energy Conservation and Efficiency, 859899 Environmentally Sustainable Energy Activities not elsewhere classified, 120202 Building Science and Techniques, 129999 Built Environment and Design not elsewhere classified, 091502 Computational Heat Transfer, Passive air cooling -- Earth pipe cooling -- Horizontal piping system -- Green roof, Book Chapter. Commercial publisher
الوصف: Earth pipe cooling technology is a building design approach for cooling a room in a passive process without using any customary units. It can reduce energy consumption of the buildings for hot and humid subtropical zones. This chapter investigates the performance of horizontal earth pipe cooling in combination with green roof system. To measure the performance, a thermal model was developed using Fluent in ANSYS 15.0. Data were collected from three air-conditioning modelled rooms installed at Central Queensland University, Rockhampton, Australia. One of the rooms was connected to a horizontal earth pipe cooling system, the second to a green roof system and the third standard room had no cooling system. The effect of air temperature, air velocity and relative humidity of the hybrid earth pipe cooling performance were assessed. A temperature reduction of 4.26ºC is predicted for a combined horizontal earth pipe cooling and green roof system compared to the standard room, which will assist the inhabitants to achieve thermal comfort and save energy in the buildings.
نوع الوثيقة: book part
اللغة: English
Relation: Thermofluid modeling for energy efficiency applications / edited by M. Masud K. Khan, Nur M.S. Hassan. London, UK : Elsevier, ©2016. Chapter 1, p. 1-30 360 pages 12 chapters 9780128023976; ACQUIRE [electronic resource] : Central Queensland University Institutional Repository.; cqu:12858; http://hdl.cqu.edu.au/10018/1038153
الاتاحة: http://hdl.cqu.edu.au/10018/1038153
Rights: © 2016 Elsevier Inc. All rights reserved.
رقم الانضمام: edsbas.D5A8A779
قاعدة البيانات: BASE