Academic Journal
Impact of magnetic data collection prior to electroanatomic model creation on acute outcomes in de novo AF procedures
العنوان: | Impact of magnetic data collection prior to electroanatomic model creation on acute outcomes in de novo AF procedures |
---|---|
المؤلفون: | Lo, M, Loguidice, M, Di Cori, A, Coluccia, G, Palmisano, P, Burns, M, Wenzel, E, Gaeta, L |
المصدر: | Europace ; volume 26, issue Supplement_1 ; ISSN 1099-5129 1532-2092 |
بيانات النشر: | Oxford University Press (OUP) |
سنة النشر: | 2024 |
الوصف: | Background As ablation and electroanatomical mapping technology evolve, workflows change to maximize the impact on procedural efficacy, safety, and efficiency. In a magnetic-primary navigation mode, optimization of the magnetic-impedance field links (VoXels) must be considered to provide accurate environments for anatomic modeling, mapping, and lesion placement. To achieve this accuracy and optimize speed of data collection, many operators have adopted the strategy of collecting VoXels using an ablation catheter prior to introduction of a multipolar mapping catheter. However, the impact of this workflow on procedural metrics has not yet been quantified in a multicenter, international cohort. Objective Assess the impact of optimizing the magnetic navigation field using an ablation catheter prior to collecting left atrial (LA) data using a high-density diagnostic tool on acute outcomes in de novo atrial fibrillation (AF) ablation procedures. Methods Acute observational data from 199 de novo pulmonary vein isolation (PVI) cases was prospectively collected from 56 operators at 42 centers in Europe, the US, and Australia. Procedural metrics, modeling workflow, ablation technology used, and acute outcomes were collected. Results Of 199 de novo AF (62.3% PAF) ablation procedures, VoXels were collected with an ablation catheter prior to LA map collection with a multipolar catheter in 65/199 (32.7%) cases; the remainder collected with multipolar catheter first. An irrigated, contact force sensing RF ablation catheter was used in all procedures. Mean procedure duration was similar in procedures in which VoXels were collected prior to map collection (VC) compared to those that did not (nVC) (107.0±46.8 min and 115.4±59.2 min, respectively (p=0.28)). Mean fluoroscopy time was significantly reduced in VC cases compared to nVC cases (3.0±4.5 min and 5.3±5.6 min, respectively (p=0.002)). Total RF duration was significantly reduced in VC cases compared to nVC cases (904±444s and 1063±632s, respectively (p=0.04)). There ... |
نوع الوثيقة: | article in journal/newspaper |
اللغة: | English |
DOI: | 10.1093/europace/euae102.163 |
الاتاحة: | http://dx.doi.org/10.1093/europace/euae102.163 https://academic.oup.com/europace/article-pdf/26/Supplement_1/euae102.163/57870760/euae102.163.pdf |
Rights: | https://creativecommons.org/licenses/by-nc/4.0/ |
رقم الانضمام: | edsbas.CAF52D99 |
قاعدة البيانات: | BASE |
DOI: | 10.1093/europace/euae102.163 |
---|