Table1_Aortic systolic and pulse pressure invasively and non-invasively obtained: Comparative analysis of recording techniques, arterial sites of measurement, waveform analysis algorithms and calibration methods.XLSX

التفاصيل البيبلوغرافية
العنوان: Table1_Aortic systolic and pulse pressure invasively and non-invasively obtained: Comparative analysis of recording techniques, arterial sites of measurement, waveform analysis algorithms and calibration methods.XLSX
المؤلفون: Daniel Bia, Yanina Zócalo, Ramiro Sánchez, Gustavo Lev, Oscar Mendiz, Franco Pessana, Agustín Ramirez, Edmundo I. Cabrera-Fischer
سنة النشر: 2023
المجموعة: Frontiers: Figshare
مصطلحات موضوعية: Physiology, Exercise Physiology, Nutritional Physiology, Reproduction, Cell Physiology, Systems Physiology, Animal Physiology - Biophysics, Animal Physiology - Cell, Animal Physiology - Systems, Comparative Physiology, Physiology not elsewhere classified, applanation tonometry, calibration, catheterism, central aortic blood pressure, invasive records, non-invasive records, oscillometry, vascular ultrasound
الوصف: Background: The non-invasive estimation of aortic systolic (aoSBP) and pulse pressure (aoPP) is achieved by a great variety of devices, which differ markedly in the: 1) principles of recording (applied technology), 2) arterial recording site, 3) model and mathematical analysis applied to signals, and/or 4) calibration scheme. The most reliable non-invasive procedure to obtain aoSBP and aoPP is not well established. Aim: To evaluate the agreement between aoSBP and aoPP values invasively and non-invasively obtained using different: 1) recording techniques (tonometry, oscilometry/plethysmography, ultrasound), 2) recording sites [radial, brachial (BA) and carotid artery (CCA)], 3) waveform analysis algorithms (e.g., direct analysis of the CCA pulse waveform vs. peripheral waveform analysis using general transfer functions, N-point moving average filters, etc.), 4) calibration schemes (systolic-diastolic calibration vs. methods using BA diastolic and mean blood pressure (bMBP); the latter calculated using different equations vs. measured directly by oscillometry, and 5) different equations to estimate bMBP (i.e., using a form factor of 33% (“033”), 41.2% (“0412”) or 33% corrected for heart rate (“033HR”). Methods: The invasive aortic (aoBP) and brachial pressure (bBP) (catheterization), and the non-invasive aoBP and bBP were simultaneously obtained in 34 subjects. Non-invasive aoBP levels were obtained using different techniques, analysis methods, recording sites, and calibration schemes. Results: 1) Overall, non-invasive approaches yielded lower aoSBP and aoPP levels than those recorded invasively. 2) aoSBP and aoPP determinations based on CCA recordings, followed by BA recordings, were those that yielded values closest to those recorded invasively. 3) The “033HR” and “0412” calibration schemes ensured the lowest mean error, and the “033” method determined aoBP levels furthest from those recorded invasively. 4) Most of the non-invasive approaches considered overestimated and underestimated aoSBP at low (i.e., 80 ...
نوع الوثيقة: dataset
اللغة: unknown
Relation: https://figshare.com/articles/dataset/Table1_Aortic_systolic_and_pulse_pressure_invasively_and_non-invasively_obtained_Comparative_analysis_of_recording_techniques_arterial_sites_of_measurement_waveform_analysis_algorithms_and_calibration_methods_XLSX/21903069
DOI: 10.3389/fphys.2023.1113972.s002
الاتاحة: https://doi.org/10.3389/fphys.2023.1113972.s002
https://figshare.com/articles/dataset/Table1_Aortic_systolic_and_pulse_pressure_invasively_and_non-invasively_obtained_Comparative_analysis_of_recording_techniques_arterial_sites_of_measurement_waveform_analysis_algorithms_and_calibration_methods_XLSX/21903069
Rights: CC BY 4.0
رقم الانضمام: edsbas.C47EF0C7
قاعدة البيانات: BASE
الوصف
DOI:10.3389/fphys.2023.1113972.s002