Academic Journal

Fluorescence Imaging Using Methylene Blue Sentinel Lymph Node Biopsy in Melanoma

التفاصيل البيبلوغرافية
العنوان: Fluorescence Imaging Using Methylene Blue Sentinel Lymph Node Biopsy in Melanoma
المؤلفون: Cwalinski T., Skokowski J., Polom W., Marano L., Swierblewski M., Drucis K., Roviello G., Cwalina N., Kalinowski L., Roviello F., Polom K.
المساهمون: Cwalinski, T., Skokowski, J., Polom, W., Marano, L., Swierblewski, M., Drucis, K., Roviello, G., Cwalina, N., Kalinowski, L., Roviello, F., Polom, K.
سنة النشر: 2022
المجموعة: Università degli Studi di Siena: USiena air
مصطلحات موضوعية: image guided surgery, surgical education, surgical oncology, Coloring Agent, Fluorescence, Fluorescent Dye, Human, Indocyanine Green, Lymph Node, Methylene Blue, Optical Imaging, Melanoma, Sentinel Lymph Node Biopsy
الوصف: Introduction: Fluorescence imaging of sentinel node biopsy in melanoma is a novel method. Both indocyanine green (ICG) and methylene blue (MB) have fluorescent properties. The aim of this study was to present, for the first time in a clinical series of patients, the possible usage of MB as a fluorescent dye for sentinel node biopsy during surgery for melanoma. Material and methods: Twenty patients with skin melanoma, who were candidates for sentinel node biopsy were enrolled in our study. All patients underwent simultaneous use of standard nanocolloid and blue dye. Transcutaneous visualization of the sentinel node, visualization of lymphatic channels as well as sentinel node fluorescent visualization were all measured. We also performed calculations of Signal to Background ratios (SBR). Results: In 15% (3/20) of patients, the fluorescent sentinel node was visible through the skin. The median SBR for the sentinel node visualization by fluorescence was 3.15 (range, 2.7–3.5). Lymphatic channels were visible in lymphatic tissue via fluorescence before visualization by the naked eye in 4 patients (20%). The median SBR ratio was 3.69 (range, 2.7–4.2). Sentinel nodes were visible by fluorescence in 13 cases (65%). The median SBR ratio was 2.49 (range, 1.5–5.7). No factors were found to be associated with fluorescent MB visualization of a sentinel node during biopsy. Conclusion: This is the first clinical study presenting the usefulness of fluorescent sentinel node biopsy in melanoma patients using MB as a fluorophore. Further studies are necessary to provide methods for its’ clinical implementation. © The Author(s) 2022.
نوع الوثيقة: article in journal/newspaper
وصف الملف: STAMPA
اللغة: English
Relation: info:eu-repo/semantics/altIdentifier/pmid/35225083; info:eu-repo/semantics/altIdentifier/wos/WOS:000780774100001; volume:29; issue:4; firstpage:503; lastpage:510; numberofpages:8; journal:SURGICAL INNOVATION; https://hdl.handle.net/11365/1234099
DOI: 10.1177/15533506221074601
الاتاحة: https://hdl.handle.net/11365/1234099
https://doi.org/10.1177/15533506221074601
https://journals.sagepub.com/doi/10.1177/15533506221074601
رقم الانضمام: edsbas.BB0CBE78
قاعدة البيانات: BASE
الوصف
DOI:10.1177/15533506221074601