Academic Journal

Negative and positive predictive values of nerve monitoring in thyroidectomy

التفاصيل البيبلوغرافية
العنوان: Negative and positive predictive values of nerve monitoring in thyroidectomy
المؤلفون: Cernea, Claudio R., Brandão, Lenine G., Hojaij, Flavio C., De Carlucci, Dorival, Brandão, José, Cavalheiro, Beatriz, Sondermann, Adriana
المصدر: Head & Neck ; volume 34, issue 2, page 175-179 ; ISSN 1043-3074 1097-0347
بيانات النشر: Wiley
سنة النشر: 2011
المجموعة: Wiley Online Library (Open Access Articles via Crossref)
الوصف: Background Recurrent nerve injury is 1 of the most important complications of thyroidectomy. During the last decade, nerve monitoring has gained increasing acceptance in several centers as a method to predict and to document nerve function at the end of the operation. We evaluated the efficacy of a nerve monitoring system in a series of patients who underwent thyroidectomy and critically analyzed the negative predictive value (NPV) and positive predictive value (PPV) of the method. Methods NIM System efficacy was prospectively analyzed in 447 patients who underwent thyroidectomy between 2001 and 2008 (366 female/81 male; 420 white/47 nonwhite; 11 to 82 years of age; median, 43 years old). There were 421 total thyroidectomies and 26 partial thyroidectomies, leading to 868 nerves at risk. The gold standard to evaluate inferior laryngeal nerve function was early postoperative videolaryngoscopy, which was repeated after 4 to 6 months in all patients with abnormal endoscopic findings. Results At the early evaluation, 858 nerves (98.8%) presented normal videolaryngoscopic features after surgery. Ten paretic/paralyzed nerves (1.2%) were detected (2 unexpected unilateral paresis, 2 unexpected bilateral paresis, 1 unexpected unilateral paralysis, 1 unexpected bilateral paralyses, and 1 expected unilateral paralysis). At the late videolaryngoscopy, only 2 permanent nerve paralyses were noted (0.2%), with an ultimate result of 99.8% functioning nerves. Nerve monitoring showed absent or markedly reduced electrical activity at the end of the operations in 25/868 nerves (2.9%), including all 10 endoscopically compromised nerves, with 15 false‐positive results. There were no false‐negative results. Therefore, the PPV was 40.0%, and the NPV was 100%. Conclusions In the present series, nerve monitoring had a very high PPV but a low NPV for the detection of recurrent nerve injury. © 2011 Wiley Periodicals, Inc. Head Neck, 2012
نوع الوثيقة: article in journal/newspaper
اللغة: English
DOI: 10.1002/hed.21695
الاتاحة: http://dx.doi.org/10.1002/hed.21695
https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1002%2Fhed.21695
https://onlinelibrary.wiley.com/doi/pdf/10.1002/hed.21695
Rights: http://onlinelibrary.wiley.com/termsAndConditions#vor
رقم الانضمام: edsbas.B50F88CF
قاعدة البيانات: BASE