Academic Journal

AC Loss Calculation on a 6.5 MVA/25 kV HTS Traction Transformer with Hybrid Winding Structure

التفاصيل البيبلوغرافية
العنوان: AC Loss Calculation on a 6.5 MVA/25 kV HTS Traction Transformer with Hybrid Winding Structure
المؤلفون: Song, Wenjuan, Jiang, Zhenan, Staines, Mike, Wimbush, Stuart, Badcock, Rodney, Fang, Jin
المصدر: Song , W , Jiang , Z , Staines , M , Wimbush , S , Badcock , R & Fang , J 2020 , ' AC Loss Calculation on a 6.5 MVA/25 kV HTS Traction Transformer with Hybrid Winding Structure ' , IEEE Transactions on Applied Superconductivity , vol. 30 , no. 4 , 9006855 . https://doi.org/10.1109/TASC.2020.2975771
سنة النشر: 2020
مصطلحات موضوعية: AC loss, hybrid winding structure, traction transformer, wire cost, /dk/atira/pure/subjectarea/asjc/2500/2504, name=Electronic, Optical and Magnetic Materials, /dk/atira/pure/subjectarea/asjc/3100/3104, name=Condensed Matter Physics, /dk/atira/pure/subjectarea/asjc/2200/2208, name=Electrical and Electronic Engineering
الوصف: HTS wire cost is a critical factor for successful commercialization of HTS traction transformer technology. Wire cost might be min-imized without significantly increasing AC loss by introducing a hybrid winding structure: the end-part of the windings is wound with high-cost high-Ic wires; the central-part of the windings is wound with low-cost low-Ic wires. We report AC loss simulation results on HTS windings with both HV and LV windings wound with REBCO wires. The 2D axisymmetric FEM simulation was carried out using H-formulation. The HV windings are wound with 4 mm-wide wires and LV windings are wound with 8/5 (eight 5 mm wide strands) Roebel cables. Both HV and LV windings have a hybrid structure in order to reduce the wire cost. Flux diverters are placed at the end of the windings to reduce AC loss. Significant HTS wire cost reduction could be achieved with-out compromising AC loss by using hybrid windings. This may help commercialize HTS traction transformer technology.
نوع الوثيقة: article in journal/newspaper
وصف الملف: application/pdf
اللغة: English
DOI: 10.1109/TASC.2020.2975771
الاتاحة: https://researchportal.bath.ac.uk/en/publications/fcc353cc-2554-4dec-9ee2-88a00b3236b3
https://doi.org/10.1109/TASC.2020.2975771
https://purehost.bath.ac.uk/ws/files/204256984/MT26_Manucript_response_28012020_.pdf
http://www.scopus.com/inward/record.url?scp=85082173012&partnerID=8YFLogxK
Rights: info:eu-repo/semantics/openAccess
رقم الانضمام: edsbas.A9721D05
قاعدة البيانات: BASE
الوصف
DOI:10.1109/TASC.2020.2975771