Academic Journal

Ex Situ Left Ventricular Pressure-Volume Loop Analyses for Donor Hearts:Proof of Concept in an Ovine Experimental Model

التفاصيل البيبلوغرافية
العنوان: Ex Situ Left Ventricular Pressure-Volume Loop Analyses for Donor Hearts:Proof of Concept in an Ovine Experimental Model
المؤلفون: Ertugrul, I. A., Puspitarani, R. A.D.A., Wijntjes, B., Vervoorn, M. T., Ballan, E. M., van der Kaaij, N. P., van Goor, H., Westenbrink, B. D., van der Plaats, A., Nijhuis, F., van Suylen, V., Erasmus, M. E.
المصدر: Ertugrul , I A , Puspitarani , R A D A , Wijntjes , B , Vervoorn , M T , Ballan , E M , van der Kaaij , N P , van Goor , H , Westenbrink , B D , van der Plaats , A , Nijhuis , F , van Suylen , V & Erasmus , M E 2024 , ' Ex Situ Left Ventricular Pressure-Volume Loop Analyses for Donor Hearts : Proof of Concept in an Ovine Experimental Model ' , Transplant International , vol. 37 , 12982 . https://doi.org/10.3389/ti.2024.12982
سنة النشر: 2024
المجموعة: University of Groningen research database
مصطلحات موضوعية: donation after circulatory death (DCD), ex situ heart perfusion, functional evaluation, heart transplantation, viability assessment
الوصف: Ex situ heart perfusion (ESHP) has emerged as an important strategy to preserve donation after brain death (DBD) and donation after circulatory death (DCD) donor hearts. Clinically, both DBD and DCD hearts are successfully preserved using ESHP. Viability assessment is currently based on biochemical values, while a reliable method for graft function assessment in a physiologic working mode is unavailable. As functional assessment during ESHP has demonstrated the highest predictive value of outcome post-transplantation, this is an important area for improvement. In this study, a novel method for ex situ assessment of left ventricular function with pressure-volume loop analyses is evaluated. Ovine hearts were functionally evaluated during normothermic ESHP with the novel pressure-volume loop system. This system provides an afterload and adjustable preload to the left ventricle. By increasing the preload and measuring end-systolic elastance, the system could successfully assess the left ventricular function. End-systolic elastance at 60 min and 120 min was 2.8 ± 1.8 mmHg/mL and 2.7 ± 0.7 mmHg/mL, respectively. In this study we show a novel method for functional graft assessment with ex situ pressure-loop analyses during ESHP. When further validated, this method for pressure-volume assessments, could be used for better graft selection in both DBD and DCD donor hearts.
نوع الوثيقة: article in journal/newspaper
وصف الملف: application/pdf
اللغة: English
DOI: 10.3389/ti.2024.12982
الاتاحة: https://hdl.handle.net/11370/e0cc87d8-d9e9-4f50-bdbc-bdf1e8974771
https://research.rug.nl/en/publications/e0cc87d8-d9e9-4f50-bdbc-bdf1e8974771
https://doi.org/10.3389/ti.2024.12982
https://pure.rug.nl/ws/files/1134446600/Ex_Situ_Left_Ventricular_Pressure-Volume_Loop_Analyses_for_Donor_Hearts-_Proof_of_Concept_in_an_Ovine_Experimental_Model.pdf
http://www.scopus.com/inward/record.url?scp=85199334292&partnerID=8YFLogxK
Rights: info:eu-repo/semantics/openAccess
رقم الانضمام: edsbas.9ABDBF39
قاعدة البيانات: BASE