Academic Journal

Paramagnetic rim lesions on 1.5T and 3.0T MRI in Mexican patients with multiple sclerosis

التفاصيل البيبلوغرافية
العنوان: Paramagnetic rim lesions on 1.5T and 3.0T MRI in Mexican patients with multiple sclerosis
المؤلفون: Rebeca de J. Ramos-Sanchez, Roger A. Carrillo-Mezo, Yazmin Martinez-Lopez, Jose Flores-Rivera, Hector Ramirez-Flores
المصدر: Journal of the Mexican Federation of Radiology and Imaging, Vol 3, Iss 1 (2024)
بيانات النشر: Permanyer
سنة النشر: 2024
المجموعة: Directory of Open Access Journals: DOAJ Articles
مصطلحات موضوعية: Medical physics. Medical radiology. Nuclear medicine, R895-920
الوصف: Introduction: Paramagnetic rim lesions (PRLs) in multiple sclerosis (MS) patients have been described with different magnetic field strengths in magnetic resonance imaging (MRI). This study aimed to identify the characteristics of PRLs in magnitude and filtered phase susceptibility weighted imaging (SWI/SWAN) in 1.5T and 3.0T MRI in Mexican patients with MS and to determine interobserver agreement. Materials and methods: This retrospective cross-sectional study assessed adults with MS who underwent 1.5T or 3.0T MRI with SWI/SWAN. The variables, sex, age, MS duration, annualized relapse rate, the severity of current disability determined by the Expanded Disability Status Scale (EDSS), the MS clinical phenotype, and the presence, number, location, and volume of PRLs were assessed. Cohen’s kappa was used to calculate interobserver agreement. Results: A total of 76 patients with MS were included. At least one PRL was found in 60 (78.9%). A total of 375 PRLs were detected: 233 in 42 (76.4%) of 55 patients with 1.5T MRI with a mean of 5.54 per patient and 142 PRLs in 18 (85.7%) of 21 patients with 3.0T MRI with a mean of 7.9 per patient. The most common location was periventricular (n = 49, 81.7%). A significant association was found between PRLs and younger patients (p = 0.017), a shorter disease evolution (p = 0.010), an annualized relapse rate (p = 0.030), and a higher volume of white matter lesions (p = 0.035). Interobserver agreement was good (κ = 0.709, 95% CI, 0.702–0.716). Conclusion: This study is the first in Mexico that characterizes PRLs with 1.5T and 3.0T MRI magnetic fields in patients with MS with good interobserver agreement.
نوع الوثيقة: article in journal/newspaper
اللغة: English
تدمد: 2938-1215
2696-8444
Relation: https://www.jmexfri.com/frame_eng.php?id=87; https://doaj.org/toc/2938-1215; https://doaj.org/toc/2696-8444; https://doaj.org/article/e883f22d26784f639917f464d59f2954
DOI: 10.24875/JMEXFRI.24000005
الاتاحة: https://doi.org/10.24875/JMEXFRI.24000005
https://doaj.org/article/e883f22d26784f639917f464d59f2954
رقم الانضمام: edsbas.97C028F9
قاعدة البيانات: BASE
الوصف
تدمد:29381215
26968444
DOI:10.24875/JMEXFRI.24000005