Academic Journal
Usage of attenuation coefficients of some tissue-equivalent materials
العنوان: | Usage of attenuation coefficients of some tissue-equivalent materials |
---|---|
المؤلفون: | TANIR, Ayşe Güneş, KETENCİ, Fatma Serap, BÖLÜKDEMİR, Mustafa Hicabi |
المصدر: | Volume: 39, Issue: 1 69-74 ; 1300-0101 ; 1303-6122 ; Turkish Journal of Physics |
بيانات النشر: | TÜBİTAK TUBITAK |
سنة النشر: | 2015 |
المجموعة: | DergiPark Akademik (E-Journals) |
مصطلحات موضوعية: | Attenuation coefficients,radiotherapy,tissue equivalent materials |
الوصف: | The total attenuation coefficients of 11 biological targets against photon energies were plotted within the energy range 1-10 MeV. From these plots a possible equation describing the relationship between photon energy and the total attenuation coefficient was derived. The suggested equation is mu/ rho = 0.0696/ surd E. To test the validity of the equation and to compare the results of the total attenuation coefficients of 3 tissue-equivalent materials (bolus, rice grains, and boiled rice) that could not be determined before, they were determined experimentally by using X-rays produced at 6 MV and 18 MV. The results of the experiment show a relatively good match with the computed values using the suggested equation. It is possible to conclude that 1) the suggested equation is a practical way to define the total attenuation coefficients of biological tissue or tissue-equivalent materials and 2) the attenuation coefficient is one of the most important to determine the absorbed dose by patients and so they should be worked out experimentally before treatment. ; The total attenuation coefficients of 11 biological targets against photon energies were plotted within the energy range 1-10 MeV. From these plots a possible equation describing the relationship between photon energy and the total attenuation coefficient was derived. The suggested equation is mu/ rho = 0.0696/ surd E. To test the validity of the equation and to compare the results of the total attenuation coefficients of 3 tissue-equivalent materials (bolus, rice grains, and boiled rice) that could not be determined before, they were determined experimentally by using X-rays produced at 6 MV and 18 MV. The results of the experiment show a relatively good match with the computed values using the suggested equation. It is possible to conclude that 1) the suggested equation is a practical way to define the total attenuation coefficients of biological tissue or tissue-equivalent materials and 2) the attenuation coefficient is one of the most important to ... |
نوع الوثيقة: | article in journal/newspaper |
وصف الملف: | application/pdf |
اللغة: | Turkish |
Relation: | https://dergipark.org.tr/tr/download/article-file/131798; https://dergipark.org.tr/tr/pub/tbtkphysics/issue/12485/150390 |
DOI: | 10.3906/fiz-1406-10 |
الاتاحة: | https://dergipark.org.tr/tr/pub/tbtkphysics/issue/12485/150390 https://doi.org/10.3906/fiz-1406-10 |
رقم الانضمام: | edsbas.9531F5B9 |
قاعدة البيانات: | BASE |
DOI: | 10.3906/fiz-1406-10 |
---|