العنوان: Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom
المؤلفون: Mainaud Durand, H, Anastasopoulos, M, Griffet, S, Kemppinen, J, Leuxe, R, Sosin, M
سنة النشر: 2011
المجموعة: CERN Document Server (CDS)
مصطلحات موضوعية: Accelerators and Storage Rings, 9: Technology for normal conducting higher energy linear accelerators
الوصف: The CLIC main beam quadrupoles need to be prealigned within 17 um rms with respect to a straight reference line along a sliding window of 200 m. A readjustment system based on eccentric cam movers, which will provide stiffness to the support assembly, is being studied. The cam movers were qualified on a 1 degree of freedom (DOF) test setup, where a repeatability of adjustment below 1um was measured along their whole range. This paper presents the 5 DOF mock-up, built for the validation of the eccentric cam movers, as well as the first results of tests carried out: resolution of displacement along the whole range, measurements of the support eigenfrequencies.
نوع الوثيقة: article in journal/newspaper
اللغة: English
Relation: info:eu-repo/grantAgreement/EC/FP7/227579; http://cds.cern.ch/record/1427722
الاتاحة: http://cds.cern.ch/record/1427722
Rights: info:eu-repo/semantics/openAccess