العنوان: Transcatheter Aortic Valve Implantation (TAVI) Planning with Dual-Layer Spectral CT Using Virtual Monoenergetic Image (VMI) Reconstructions and 20 mL of Contrast Media
المؤلفون: Fontana, Federico, Piacentino, Filippo, Gnesutta, Aroa, Macchi, Edoardo, Coppola, Andrea, Saccomanno, Angiola, Gatta, Tonia, Recaldini, Chiara, Minenna, Manuela, Tamborini, Claudio, Dossi, Filippo, Ascenti, Velio, Barbera, Simone, Cicero, Giuseppe, Carcano, Giulio, Ascenti, Giorgio, Castiglioni, Battistina, Venturini, Massimo
المساهمون: Fontana, Federico, Piacentino, Filippo, Gnesutta, Aroa, Macchi, Edoardo, Coppola, Andrea, Saccomanno, Angiola, Gatta, Tonia, Recaldini, Chiara, Minenna, Manuela, Tamborini, Claudio, Dossi, Filippo, Ascenti, Velio, Barbera, Simone, Cicero, Giuseppe, Carcano, Giulio, Ascenti, Giorgio, Castiglioni, Battistina, Venturini, Massimo
سنة النشر: 2024
المجموعة: IRInSubria - Institutional Repository Insubria (Università degli Studi dell’Insubria)
مصطلحات موضوعية: TAVI planning, dual-layer spectral CT, image quality, iodine load reduction, patient safety, transcatheter aortic valve implantation, vascular anatomy assessment, virtual monoenergetic images
الوصف: Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to surgical implantation and its implementation is progressively increasing worldwide. We routinely perform pre-procedural aortic angiography CT to assess aortic dimensions and vascular anatomy. This study aims to evaluate the image quality of CTA for TAVI planning using dual-layer spectral CT, with virtual monoenergetic image reconstructions at 40 keV. Thirty-one patients underwent a CTA protocol with the injection of 20 mL of contrast media. Image quality was assessed by measuring the mean density in Hounsfield Units (HU), the signal-to-noise ratio, and the contrast-to-noise ratio in VMI reconstructions. Additionally, a blinded subjective analysis was conducted by two observers. The results showed significant enhancement at all sampled vascular levels with a gradual decrease in HU from proximal to distal regions. Favourable subjective ratings were given for all parameters, with greater variability in the evaluation of iliac axes. A significant negative correlation (p < 0.05) was observed between BMI and CA at all vascular levels, indicating reduced contrast enhancement with increasing BMI. Spectral CT, along with reducing iodine load, allows for obtaining high-quality images without a significant increase in noise. The reduction in iodine load can have positive implications in clinical practice, improving patient safety and resource efficiency.
نوع الوثيقة: article in journal/newspaper
وصف الملف: ELETTRONICO
اللغة: English
Relation: info:eu-repo/semantics/altIdentifier/pmid/38256659; info:eu-repo/semantics/altIdentifier/wos/WOS:001153030200001; volume:13; issue:2; firstpage:1; lastpage:14; numberofpages:14; journal:JOURNAL OF CLINICAL MEDICINE; https://hdl.handle.net/11383/2166853; info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85183379360
DOI: 10.3390/jcm13020524